Milwaukee


  • Milwaukee MA9070 Zero Oxygen Calibration Solution Kit Accessory Milwaukee

    Milwaukee Milwaukee MA9070 Zero Oxygen Calibration Solution Kit

    The MA9070 Zero Oxygen Calibration Solution Kit is made up of two components for use in calibrating the Milwaukee MW600 DO Meter. Design Features Easy to use Simple mix the two components and place in solution to quickly calibrate to 0% oxygen concentration Traceable Product labeled with product code, lot number and expiration date Secure Air tight bottle with tamper-proof seal

    $26.00

  • Milwaukee M10032B 1382 ppm TDS Calibration Solution Sachet Sachet Milwaukee

    Milwaukee Milwaukee M10032B 1382 ppm TDS Calibration Solution Sachet

    The performance of conductivity probes are affected by use due to residue build up and aging. M10032B is a lab grade 1382 ppm TDS solution standard prepared against a NIST traceable potassium chloride solution that allows you to recalibrate your conductivity meter or tester. Check your meter or tester's manual to find the correct calibration standard for your meter. TDS readings are effected by temperature. To help with this, a chart of the actual ppm value at various temperatures is printed on each sachet. Milwaukee TDS solutions are labelled with the lot number and expiration date and packaged in an air tight, tamper-proof sachet. DESIGN FEATURES Fundamental for accurate TDS measurement. Factory calibrated with potassium chloride NIST 2202 SRM (Standard Reference Material) in deionized water for analytical use in accordance with ISO 3696/BS3978. Sealed against light and air. Ideal for on-the-spot calibration Simply open, insert the tester or electrode into the sachet and calibrate Each 20 mL sachet is marked with lot number and expiration date. A temperature chart of the actual ppm value at various temperatures is printed on each sachet. 5 year expiry date.

    $2.00

  • Milwaukee M10016B Electrode Cleaning Solution Sachet Sachet Milwaukee

    Milwaukee Milwaukee M10016B Electrode Cleaning Solution Sachet

    Electrode cleaning solution is ideal for cleaning all pH, ORP and TDS meter's probes. To help maintain high performance and accuracy for any electrode, regular cleaning is required to remove the build up of dirt and sediment on the glass or carbon surfaces of a sensing probe. Use M10016B to help extend the life of the meter's electrode. Electrode cleaning solution should not be a substitute for rinse and or storage solutions. Sachet packaging means that you get fresh solution every time. Ideal for infrequent or field use. No risk of using an expired calibration solution. Milwaukee cleaning solutions are designed to help you achieve reliable and repeatable measurements while extending the life of your electrode. DESIGN FEATURES Electrode Cleaning Solution - 20 mL (box of 25). Fundamental for gently cleaning the electrode between uses and before storage. Sealed against light and air. Ideal for on-the-spot cleaning too. Simply open, insert the tester or electrode into the sachet and gently stir let soak for 15 minutes. Formulated with a 5 year expiry

    $2.00

  • Milwaukee EC59 PRO Waterproof 3-in-1 Conductivity / TDS & Temperature Tester with Replaceable Probe (FBA) Pocket Tester Milwaukee

    Milwaukee Milwaukee EC59 PRO Waterproof 3-in-1 Conductivity / TDS & Temperature Tester with Replaceable Probe

    The Milwaukee EC59 PRO Conductivity (EC) & Total Dissolved Solids (TDS) Tester is designed for aquaculture, food, wine, laboratory, water treament and many other applications. It is the ideal meter to help make sure that your EC/TDS/Temp. needs are being met and are reliable results for your analysis. Keep EC/TDS/TEMP. in your target range to help your achieve best results. DESIGN FEATURES Measures EC/TDS/Temp. with automatic temperature compensation (ATC). Ideal range for all different applications (0 to 3999 uS/cm) | 0 to 2000 ppm | 0.0 to 60°C (32.0 to 140.0°F). Units in uS/cm or ppm easily convertable to other ranges. Factory calibrated with the ability to recalibrate if needed. Replaceable electrode Mi59P. Fully waterproof to IP65. Approximately 100 hours of use (4 x 1.5V batteries included). CARE AND USE MAINTENANCE EC electrodes can develop nutrient build up over time. To miminize build up, always rinse the probe in fresh tap water after every use. CONVERTING EC TO TDS The Milwaukee PRO Conductivity Tester, like all conductivity meters, provides a measure of electrically charged ions in a solution and is an absolute measure of conductivity. EC/TDS can converted. Different scales include the 500 scale, 650 scale and the 700 scale. Your uS/cm reading can be approximately converted to other scales as shown in the examples below. 2.00 mS/cm = 2000 uS/cm = 1000 ppm on .50 factor scale 2.00 mS/cm = 2000 uS/cm = 1400 ppm on the 442 scale or .70 factor scale

    $90.00

  • Milwaukee MW600 PRO Dissolved Oxygen Meter (includes calibration solutions) Pocket Tester Milwaukee

    Milwaukee Milwaukee MW600 PRO Dissolved Oxygen Meter (includes calibration solutions)

    The Milwaukee MW600 PRO Portable Dissolved Oxygen meter is one of Milwaukee's most popular meters with its reliable and fast operation as well as its accuracy. The Milwaukee PRO DO Meter is preferred by people looking for lab level accuracy without the cost. The Milwaukee DO Meter is popular with everyone from field biologists and educators to fish farmers and koi pond owners. DESIGN FEATURES Fast, easy-to-read results with large digital LCD readout Repeatable, accuracy to ±1.5% FS Lightweight and portable Simple 2 point open air calibration (see video below) Uses MA840 reinforced polarographic probe with an oxygen-permeable polytetrafluorethylene (PTFE) membrane sensor 5 O-rings, membranes and one protective cap included 10 feet probe cable for extra flexibility when testing 70 hours of battery life with continuous use (battery included) with low battery warning CARE AND USE “OPEN AIR” CALIBRATION PROCEDURE 1. Remove the membrane Take the membrane off the end of the probe and dry the diode off. 2. Zero out the display Connect the probe to the base unit and turn the unit on. Your display should read 0.0. If it does not, go to the position “0” screw on the front of the unit with the screw driver provided and through the access hole make the unit display read 0.0. 3. Fill the membrane Go to the membrane and put the “O” ring inside the membrane on the shoulder at the base of the threads. Fill the membrane to just short of the “O” ring with MA9071 electrolyte solution. Be sure that there are no bubbles inside the membrane. (Air bubbles are the main cause of calibration failure) 4. Attach the membrane Screw the membrane on to the probe. 5. Let stablize Turn the meter on and hang the probe off the end of a table pointing down and let the unit display stabilize (this may take 5 to 15 minutes) 6. Adjust Push down and hold the “Cal” button on the front face of the meter and with the screwdriver go to the front Cal position “100%” and make the display read 100. You are now calibrated. EXTRA TIPS Watch for the membrane having wrinkles or stretch marks. If you see wrinkles, replace with a new membrane. Always use fresh electrolyte solution (MA9071). DOWNLOAD EXCEL WORKSHEET FOR TEMPERATURE COMPENSATION ON MW600 DO METER (XLS) Determine water temperature, insert reading from meter display, and this worksheet will automatically calculate a temperature-compensated DO reading for you.

    $379.00

  • 25pk Milwaukee M10007B pH 7.01 Calibration Solution Sachet Accessory Milwaukee

    Milwaukee 25pk Milwaukee M10007B pH 7.01 Calibration Solution Sachet

    Probe calibration is a simple procedure for optimal performance and should be done any time your readings become suspect. Calibration should be performed at least once a month. M10007B is a lab grade pH 7.01 calibration solution certified to meet the standard with an accuracy of ±0.01 pH removing the inaccuracies involved with mixing solutions from powder. Sachet packaging means that you get fresh solution every time. Ideal for infrequent or field use. No risk of using an expired calibration solution. Milwaukee solutions are designed to help you achieve reliable and repeatable pH measurements while extending the life of your electrode. DESIGN FEATURES pH 7.01 Calibration Buffer Solution - 20 mL Fundamental for the correct use of electrodes and for obtaining the most accurate and reproducible readings Sealed against light and air Ideal for on-the-spot calibration Simply open, insert the tester or electrode into the sachet and calibrate Formulated with a 5 year expiry Colour coded for easy identification

    $30.00

  • Milwaukee M10031B 1413 µS/cm Conductivity Calibration Solution Sachet Sachet Milwaukee

    Milwaukee Milwaukee M10031B 1413 µS/cm Conductivity Calibration Solution Sachet

    The performance of conductivity probes are affected by use due to residue build up and aging.  M10031B is a lab grade 1413 µS/cm conductivity solution standard prepared against a NIST traceable potassium chloride solution that allows you to recalibrate your conductivity meter or tester. Check your meter or tester's manual to find the correct calibration standard for your meter. Conductivity readings are effected by temperature. To help with this, a chart of the actual µS/cm value at various temperatures is printed on each sachet. Milwaukee conductivity solutions are labeled with the lot number and expiration date and packaged in an air tight, tamper-proof sachet. Design Features Fundamental for accurate conductivity measurement. Factory calibrated with potassium chloride NIST 2202 SRM (Standard Reference Material) in deionized water for analytical use in accordance with ISO 3696/BS3978. Sealed against light and air. Ideal for on-the-spot calibration Simply open, insert the tester or electrode into the sachet and calibrate Each 20 mL sachet is marked with lot number and expiration date. A temperature chart of the actual µS/cm value at various temperatures is printed on each sachet. 5 year expiry date.

    $2.00

  • 25pk Milwaukee M10004B pH 4.01 Calibration Solution Sachet Accessory Milwaukee

    Milwaukee 25pk Milwaukee M10004B pH 4.01 Calibration Solution Sachet

    M10004B is a lab grade pH 4.01 buffer solution certified to meet the standard to an accuracy of ±0.01 pH removing the inaccuracies involved with mixing calibration solutions from powder. Sachet packaging means that you get fresh solution every time. Ideal for infrequent or field use. No risk of using expired calibration solution. Milwaukee solutions are designed to help you achieve reliable and repeatable pH measurements while extending the life of your electrode. DESIGN FEATURES pH 4.01 Calibration Buffer Solution - 20 mL Fundamental for the correct use of electrodes and for obtaining the most accurate and reproducible readings Sealed against light and air Ideal for on-the-spot calibration Simply open, insert the tester or electrode into the sachet and calibrate Formulated with a 5 year expiry Colour coded for easy identification

    $30.00

  • Last stock! Milwaukee MW803 MAX Waterproof Low Range 4-in-1 pH / EC / TDS/Temp Tester with Replaceable Probe Handheld Meter Milwaukee

    Milwaukee Milwaukee MW803 MAX Waterproof Low Range 4-in-1 pH / EC / TDS/Temp Tester with Replaceable Probe

    The Milwaukee MW803 MAX Waterproof Low Range 4-in-1 pH/EC/TDS/Temp Tester is designed as an all-in-one solution for growers. The Milwaukee MW803 MAX Waterproof 4-in-1 Tester offers: ACCURACY The MW803 MAX 4-in-1 tester is accurate to ±0.05 pH, EC/TDS to 2% Full Scale and ±0.5°C / ±1°F for temperature. With automatic calibration and 5 memorized calibration points, the tester can be quickly and easily be calibrated to a higher accuracy compared with manual calibration. LONG LIFE The tester comes with a replaceable pH probe with a double junction probe design for longer life. FAST RESPONSE An exposed temperature probe is located close to the pH probe for fast temperature compensation. WATERPROOF CONSTRUCTION No more worries about dropping your tester while measuring. The MW803 is fully waterproof to IP65. LIGHT WEIGHT At just 3.5 ounces, the MW803 MAX is easy to handle at up to half the weight of other testers. EASE-OF-USE A large dual level LCD screen makes reading results easy while a stability indicator and hold function that freezes the display takes the guess work out. DESIGN FEATURES Fast easy to read results with large digital dual LCD readout. Extreme accuracy to ±0.05 pH, EC / TDS 2% Full Scale and Temperature ±0.5 C / ±1 F. Range 0.00 – 14.00 pH | EC 0 to 3999 uS/cm | TDS 0 - 2000 ppm | Temperature: 0.0 to 50.0 C / 32.0 to 122.0 F. Lightweight and portable at just 3.5 ounces. Easy measurement: just place the probe in the sample, gently stir, wait for the stability indication to show a stable reading and then freeze the reading. Simple push button, automatic 1 or 2 point pH calibration with 5 saved calibration points and simple 1 point EC calibration. Gel-filled, double junction pH electrode for low maintenance and high performance with exposed temp. sensor for fast readings. Auto shut off after 8 minutes of non-use. Fully waterproof to IP65. Battery life approx. 100 hour of continuous use (batteries included). CARE AND USE The MW803 PRO Tester includes both a pH and EC electrode. Both need maintenance. All pH sensors have a limited life and response time gets longer with age. Properly maintaining your pH pen tester will give you fast, accurate results for longer. So, be sure to order the Milwaukee pH Maintenance Kit code PH-Main at checkout time! This will be needed to help clean and condition the pH electrode before use! EC sensors are more robust but can still be affected by residue build up. Here are our top four tips. 1. Always store with the cap full of buffer or storage solution MA9015 not water. 2. Clean your Tester regularly by soaking in cleaning solution MA9016. 3. Calibrate after cleaning and/or storage before testing to adjust for changes in the pH and EC sensor. 4. Gently stir the PRO Tester in the sample for a faster result. 5. Rinse in water after every test. Thank you for considering Milwaukee to help you take your results to the next level.

    $219.00

  • Milwaukee T75 Waterproof Low Range Total Dissolved Solids Pen (TDS) (FBA) Handheld Meter Milwaukee

    Milwaukee Milwaukee T75 Waterproof Low Range Total Dissolved Solids Pen (TDS)

    The Milwaukee T75 Waterproof Total Dissolved Solids (TDS) Pen is designed for, aquariums, aquaculture, education, water conditioning and many other applications. The T75 helps you make sure that your fish have the right TDS balance to help them stay healthy. TDS also help keep filters up-to-date and clean for water filtration. Keep TDS in your target range to help your achieve better results. DESIGN FEATURES Measures Total Dissolved (TDS) direct and with automatic temperature compensation. Easy-to-read LCD. Ideal range for aquariums (0 to 1999 ppm). Units in ppm easily convertible to uS/cm. Factory calibrated with the ability to recalibrate if needed. 250 hours continuous use (3 x 1.5V batteries included). Simple one point calibration. Fully waterproof to IP65 Replaceable TDS electrode MA73075. CARE AND USE MAINTENANCE TDS/PPM electrodes can develop nutrient build up over time. To miminice build up, always rinse the probe in fresh tap or DI water after every use. CONVERTING TDS TO EC The Milwaukee TDS Pen, like all TDS meters, provides a measure of Total Dissolved Solids (ppm) reading, of contaminates per unit of volume in a solution. TDS/PPM is often converted to uS/cm. Different scales include the 500 scale, 650 scale and the 700 scale. Your TDS/PPM readings can be approximately converted to uS/cm as shown in the examples below. 1 ppm = 2 uS/cm on the 0.5 factor scale 1 ppm = 1.43 µS/cm on the 442 scale or .70 factor scale Thank you for considering Milwaukee to help you take your results to the next level.

    $51.00

  • Milwaukee CD600 Digital Total Dissolved Solids Pen (TDS) Pocket Tester Milwaukee

    Milwaukee Milwaukee CD600 Digital Total Dissolved Solids Pen (TDS)

    The Milwaukee CD600 Total Dissolved Solids (TDS) Pen is designed for hydroponics, aquariums, horticulture, water conditioning and many other applications. The CD600 helps you make sure that your plants are receiving the right amount of nutrient or helps you keep your filters up-to-date and clean for water filtration. Keep TDS in your target range to help your achieve better results. DESIGN FEATURES Measures Total Disolved (TDS) direct and with automatic temperature compensation. Ideal range for hydroponics (0 to 1990 ppm). Units in ppm easily convertable to uS/cm. Factory calibrated with the ability to recalibrate if needed. Automatic Temperature Compensation (ATC). 350 hours continuous use (4 x 1.5V batteries included). Simple one point calibration. CARE AND USE MAINTENANCE TDS/PPM electrodes can develop nutrient build up over time. To miminize build up, always rinse the probe in fresh tap or DI water after every use. CONVERTING TDS TO EC The Milwaukee TDS Pen, like all TDS meters, provides a measure of Total Dissolved Solids (ppm) reading, of contaminates per unit of volume in a solution. TDS/PPM is often converted to uS/cm. Different scales include the 500 scale, 650 scale and the 700 scale. Your TDS/PPM readings can be approximately converted to uS/cm as shown in the examples below. 1 ppm = 2 uS/cm on the 0.5 factor scale 1 ppm = 1.43 µS/cm on the 442 scale or .70 factor scale Thank you for considering Milwaukee to help you take your results to the next level.

    $38.00

  • Milwaukee CD601 Digital Conductivity Pen (EC) (FBA) Pocket Tester Milwaukee

    Milwaukee Milwaukee CD601 Digital Conductivity Pen (EC)

    The Milwaukee CD601 digital electrical conductivity (EC) Pen is designed for aquariums, aquaculture, pools, water conditioning and many other applications. The CD601 helps you make sure that your water has the right amount of nutrient to help keep fish tanks healthy or helps you keep your filters up-to-date and clean for water filtration. Keep EC in your target range to help your achieve better results. DESIGN FEATURES Measures microSiemens (uS/cm) direct and with automatic temperature compensation. Ideal range for aquariums (0 to 1990 uS/cm). Units in uS/cm are easily convertible to (ppm). Factory calibrated with the ability to recalibrate if needed. Automatic Temperature Compensation (ATC). 350 hours continuous use (4 x 1.5V batteries included). Simple one point calibration. CARE AND USE MAINTENANCE EC electrodes can develop nutrient build up over time. To miminise build up, always rinse the probe in fresh tap or DI water after every use. CONVERTING EC TO TDS The Milwaukee EC Pen, like all conductivity meters, provides a measure of electrically charged ions in a solution and is an absolute measure of conductivity. EC is often converted to TDS in parts per million (ppm). Different scales include the 500 scale, 650 scale and the 700 scale. However, true PPM can only be determined through chemical analysis. Your mS/cm reading can be approximately converted to TDS (ppm) as shown in the examples below. 2,000 µS/cm = 2.0 mS/cm = 1000 ppm on .50 factor scale 2,000 µS/cm = 2.0 mS/cm = 1400 ppm on the 442 scale or .70 factor scale Thank you for considering Milwaukee to help you take your results to the next level.

    $38.00


© 2025 GroAqua, Powered by Shopify

    • American Express
    • Apple Pay
    • Diners Club
    • Discover
    • Google Pay
    • Klarna
    • Maestro
    • Mastercard
    • PayPal
    • Shop Pay
    • Union Pay
    • Visa

    Login

    Forgot your password?

    Don't have an account yet?
    Create account