The performance of conductivity probes are affected by use due to residue build up and aging. M10030 is a lab grade 12880 µS/cm conductivity solution standard prepared against a NIST traceable potassium chloride solution that allows you to recalibrate your conductivity meter or tester. Check your meter or tester's manual to find the correct calibration standard for your meter. Conductivity readings are effected by temperature. To help with this, a chart of the actual µS/cm value at various temperatures is printed on each sachet. Milwaukee conductivity solutions are labeled with the lot number and expiration date and packaged in an air tight, tamper-proof sachet. Design Features Fundamental for accurate conductivity measurement. Factory calibrated with potassium chloride NIST 2202 SRM (Standard Reference Material) in deionized water for analytical use in accordance with ISO 3696/BS3978. Sealed against light and air. Ideal for on-the-spot calibration Simply open, insert the tester or electrode into the sachet and calibrate Each 20 mL sachet is marked with lot number and expiration date. A temperature chart of the actual µS/cm value at various temperatures is printed on each sachet. 5 year expiry date.
The performance of conductivity probes are affected by use due to residue build up and aging. M10031B is a lab grade 1413 µS/cm conductivity solution standard prepared against a NIST traceable potassium chloride solution that allows you to recalibrate your conductivity meter or tester. Check your meter or tester's manual to find the correct calibration standard for your meter. Conductivity readings are effected by temperature. To help with this, a chart of the actual µS/cm value at various temperatures is printed on each sachet. Milwaukee conductivity solutions are labeled with the lot number and expiration date and packaged in an air tight, tamper-proof sachet. Design Features Fundamental for accurate conductivity measurement. Factory calibrated with potassium chloride NIST 2202 SRM (Standard Reference Material) in deionized water for analytical use in accordance with ISO 3696/BS3978. Sealed against light and air. Ideal for on-the-spot calibration Simply open, insert the tester or electrode into the sachet and calibrate Each 20 mL sachet is marked with lot number and expiration date. A temperature chart of the actual µS/cm value at various temperatures is printed on each sachet. 5 year expiry date.
The performance of conductivity probes are affected by use due to residue build up and aging.
M10032B is a lab grade 1382 ppm TDS solution standard prepared against a NIST traceable potassium chloride solution that allows you to recalibrate your conductivity meter or tester. Check your meter or tester's manual to find the correct calibration standard for your meter.
TDS readings are effected by temperature. To help with this, a chart of the actual ppm value at various temperatures is printed on each sachet.
Milwaukee TDS solutions are labelled with the lot number and expiration date and packaged in an air tight, tamper-proof sachet.
DESIGN FEATURES
Fundamental for accurate TDS measurement.
Factory calibrated with potassium chloride NIST 2202 SRM (Standard Reference Material) in deionized water for analytical use in accordance with ISO 3696/BS3978.
Sealed against light and air.
Ideal for on-the-spot calibration
Simply open, insert the tester or electrode into the sachet and calibrate
Each 20 mL sachet is marked with lot number and expiration date.
A temperature chart of the actual ppm value at various temperatures is printed on each sachet.
5 year expiry date.
The performance of conductivity probes are affected by use due to residue build up and aging.
M10038B is a lab grade 6.44 ppt TDS solution standard prepared against a NIST traceable potassium chloride solution that allows you to recalibrate your conductivity meter or tester. Check your meter or tester's manual to find the correct calibration standard for your meter.
TDS readings are effected by temperature. To help with this, a chart of the actual ppm value at various temperatures is printed on each sachet.
Milwaukee TDS solutions are labelled with the lot number and expiration date and packaged in an air tight, tamper-proof sachet.
DESIGN FEATURES
Fundamental for accurate TDS measurement.
Factory calibrated with potassium chloride NIST 2202 SRM (Standard Reference Material) in deionized water for analytical use in accordance with ISO 3696/BS3978.
Sealed against light and air.
Ideal for on-the-spot calibration
Simply open, insert the tester or electrode into the sachet and calibrate
Each 20 mL sachet is marked with lot number and expiration date.
A temperature chart of the actual ppm value at various temperatures is printed on each sachet.
5 year expiry date.
The Milwaukee MA73600 is the replacement pH/temperature probe for the pH51 & pH54 Testers (sold separately).
The MA73600 measures pH and easily slides into the tester fitting then screws into the meter body for secure installation.
The Milwaukee MA841 Dissolved Oxygen Membranes are compatible with the MA840 Polarographic Dissolved Oxygen Probe used on the MW600 Dissolved Oxygen Meter. Design features Oxygen-permeable polytetrafluroethylene (PTFE) membrane sensor Easy to fill with MA9071 Oxygen Electrolyte Solution Includes membranes and 5 o-rings
MA9015 is a lab grade electrode storage solution prepared with premium chemicals to improve the performance and extend the life of your pH and ORP electrodes, testers and pens.
To ensure a quick response and free-flowing liquid junction, the sensing element and reference junction must not be allowed to dry out. Properly storing your pH electrode in a solution keeps the glass membrane well hydrated which maintains proper function and provides accurate readings.
MA9015 also helps keep the junction in your pH and ORP electrode flowing which is critical for fast results.
DESIGN FEATURES
Fundamental for the correct use of electrodes and for obtaining the most accurate and reproducible readings.
Formulated to minimize organic growth on your electrode.
Sealed against light with air tight, tamper proof cap.
Factory blended to precise standards in a dedicated, temperature controlled environment.
Simply open and add to the cap of your electrode or tester.
Each bottle marked with lot number and expiration date.
MA9016 is a lab grade electrode cleaning solution prepared with premium chemicals to improve the performance and extend the life of your pH and ORP electrodes, testers and pens.
Your accuracy and speed of your results are dependent on your pH sensing bulb and ORP platinum tip being clean. pH and ORP electrodes also need a free flowing junction to function.
Milwaukee's cleaning solution helps both keep sensing parts clean and the junction open. Simply open the bottle, fill a beaker or container so that the level covers the sensor and junction, and soak for 15 to 20 minutes followed by a soaking in MA9015 storage solution for at least 2 hours.
DESIGN FEATURES
Fundamental for the correct use of electrodes and for obtaining the most accurate and reproducible readings.
Specially formulated for cleaning electrodes
Factory blended to precise standards in a dedicated, temperature controlled environment.
Sealed against light with air tight, tamper proof cap.
Each bottle marked with lot number and expiration date.
MA9020 is a lab grade ORP 200-275 mV solution certified to meet the range. MA9020 is used to check the health and accuracy of an ORP electrode.
Milwaukee solutions are designed to help you achieve reliable and repeatable ORP measurements.
DESIGN FEATURES
OPR 200-275 mV solution value (230 mL).
Fundamental for the correct use of ORP electrodes and for obtaining the most accurate and reproducible readings.
Sealed against light with air tight, tamper proof cap.
Ideal for fast accuracy check.
Simply open, pour into a beaker or container and insert the tester or electrode to start the ORP mV check process.
The MA9070 Zero Oxygen Calibration Solution Kit is made up of two components for use in calibrating the Milwaukee MW600 DO Meter.
Design Features
Easy to use
Simple mix the two components and place in solution to quickly calibrate to 0% oxygen concentration
Traceable
Product labeled with product code, lot number and expiration date
Secure
Air tight bottle with tamper-proof seal
The MA9071 electrolyte fill solution is designed for Milwaukee's polarographic dissolved oxygen probe. A high quality electrolyte solution is crucial to the performance of your dissolved oxygen probe.
DESIGN FEATURES
PRECISE FORMULATION
Factory mixed using reagent grade chemicals in a dedicated, temperature controlled environment.
TRACEABLE
Product labeled with product code, lot number and expiration date.
SECURE
Air tight bottle with tamper-proof seal.
USE AND CARE
“OPEN AIR” CALIBRATION PROCEDURE FOR THE MW600 DISSOLVED OXYGEN METER
1. Remove the membrane
Take the membrane off the end of the probe and dry the diode off.
2. Zero out the display
Connect the probe to the base unit and turn the unit on. Your display should read 0.0. If it does not, go to the position “0” screw on the front of the unit with the screw driver provided and through the access hole make the unit display read 0.0.
3. Fill the membrane
Go to the membrane and put the “O” ring inside the membrane on the shoulder at the base of the threads. Fill the membrane to just short of the “O” ring with MA9071 electrolyte solution. Be sure that there are no bubbles inside the membrane. (Air bubbles are the main cause of calibration failure)
4. Attach the membrane
Screw the membrane on to the probe.
5. Let stabilize
Turn the meter on and hang the probe off the end of a table pointing down and let the unit display stabilize (this may take 5 to 15 minutes)
6. Adjust
Push down and hold the “Cal” button on the front face of the meter and with the screwdriver go to the front Cal position “100%” and make the display read 100.
You are now calibrated.
EXTRA TIPS
Watch for the membrane having wrinkles or stretch marks. If you see wrinkles, replace with a new membrane.
Always use fresh electrolyte solution (MA9071).
The Milwaukee MI56P is the replacement pH/temperature probe for the pH55 and pH56 PRO Testers (sold separately).
The MI56P measures pH and temperature and easily slides into the tester fitting then screws into the meter body for secure installation.