{"product_id":"milwaukee-ma9071-oxygen-electrolyte-solution","title":"Milwaukee MA9071 Oxygen Electrolyte Solution","description":"\u003cdiv data-mce-fragment=\"1\"\u003eThe MA9071 electrolyte fill solution is designed for Milwaukee's polarographic dissolved oxygen probe. A high quality electrolyte solution is crucial to the performance of your dissolved oxygen probe.\u003c\/div\u003e\n\u003ch2 data-mce-fragment=\"1\"\u003eDESIGN FEATURES\u003c\/h2\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003ePRECISE FORMULATION\u003c\/b\u003e\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003eFactory mixed using reagent grade chemicals in a dedicated, temperature controlled environment.\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eTRACEABLE\u003c\/b\u003e\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003eProduct labeled with product code, lot number and expiration date.\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eSECURE\u003c\/b\u003e\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003eAir tight bottle with tamper-proof seal.\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eUSE AND CARE\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e“OPEN AIR” CALIBRATION PROCEDURE FOR THE MW600 DISSOLVED OXYGEN METER\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e1. Remove the membrane\u003c\/b\u003e\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003eTake the membrane off the end of the probe and dry the diode off.\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e2. Zero out the display\u003c\/b\u003e\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003eConnect the probe to the base unit and turn the unit on. Your display should read 0.0. If it does not, go to the position “0” screw on the front of the unit with the screw driver provided and through the access hole make the unit display read 0.0.\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e3. Fill the membrane\u003c\/b\u003e\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003eGo to the membrane and put the “O” ring inside the membrane on the shoulder at the base of the threads. Fill the membrane to just short of the “O” ring with MA9071 electrolyte solution. Be sure that there are no bubbles inside the membrane. (Air bubbles are the main cause of calibration failure)\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e4. Attach the membrane\u003c\/b\u003e\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003eScrew the membrane on to the probe.\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e5. Let stabilize\u003c\/b\u003e\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003eTurn the meter on and hang the probe off the end of a table pointing down and let the unit display stabilize (this may take 5 to 15 minutes)\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003e6. Adjust\u003c\/b\u003e\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003ePush down and hold the “Cal” button on the front face of the meter and with the screwdriver go to the front Cal position “100%” and make the display read 100.\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003e\u003cb data-mce-fragment=\"1\"\u003eYou are now calibrated.\u003c\/b\u003e\u003c\/div\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003eEXTRA TIPS\u003c\/h3\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003eWatch for the membrane having wrinkles or stretch marks. If you see wrinkles, replace with a new membrane.\u003c\/div\u003e\n\u003cdiv data-mce-fragment=\"1\"\u003eAlways use fresh electrolyte solution (MA9071).\u003c\/div\u003e","brand":"Milwaukee","offers":[{"title":"Default Title","offer_id":47907585098042,"sku":"MS-MA9071","price":55.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0247\/9531\/6278\/files\/milwaukee-ma9071-oxygen-electrolyte-solution-ms-ma9071-2212743.jpg?v=1757078494","url":"https:\/\/groaqua.store\/en-nz\/products\/milwaukee-ma9071-oxygen-electrolyte-solution","provider":"GroAqua","version":"1.0","type":"link"}