YSI ProDIGITAL ODO Cable

Description

The ODO/T probe assembly pairs with the ProSolo Handheld to form a complete sampling system. Please visit the ProSolo ODO/T Kits page for fully assembled systems.
  • Featuring integral, digital sensors, the ODO/T is plug-and-play which minimizes time spent on instrument setup. ProDIGITAL technology allows the handheld to automatically recognize connected sensors, so there is no need to tell the instrument what is connected. Optical Dissolved Oxygen (ODO) technology is non-consumptive, meaning oxygen is not consumed during the measurement. Flow dependence is non-existent and no stirring is required, resulting in the most accurate DO measurements available from a probe. The ODO sensor is not susceptible to interferences from other gases, drifts less and holds calibration longer than membrane covered sensors. Maintenance is a breeze with a simple, threaded optical cap that is good for at least two years.

    The ProDIGITAL ODO/T probe and cable assembly features include:

    Integral optical dissolved oxygen, and temperature sensors that are auto-recognized by ProDIGITAL handhelds, reducing instrument set-up time
    Rugged Optical DO sensor cap with a 2-year warranty is pre-installed on new assemblies
    Military Spec (MS) connector and a weighted, stainless steel probe guard
    Fits in a 1 inch well with cable lengths up to 100 meters
    2-year warranty on cable, sensors, and ODO cap

    Acuracy

    Temperature - ±0.2 °C

    Dissolved Oxygen - 0 to 200%: ±1% of reading or 1% saturation, whichever is greater 200 to 500%: ±8% of reading 0 to 20 mg/L: ±0.1 mg/L or 1% of reading, whichever is greater 20 to 50 mg/L: ±8% of reading

    Measurement Method / Channels Temperature - Thermistor; Dissolved Oxygen - Optical luminescence - lifetime method
    Measurement Range

    Temperature - -5 to 70 °C (temperature compensation range for DO mg/L measurement: -5 to 50 °C )

    Dissolved Oxygen - 0 to 500%, 0 to 50 mg/L

    Parameters Measured

    Dissolved Oxygen, Temperature

    Size

    Width - 2.46 cm (0.97 in.)

    Unit of Measure Temperature - °C, °F, K; Dissolved Oxygen - % saturation, % saturation local, mg/L, ppm
    Warranty

    Warranty 2-year probe and cable assembly; 2-year extended warranty ODO sensor cap

YSI ProDIGITAL ODO Cable

Product form

Free pickup in our shop(s)

£848.40 Incl. VAT

    NOTIFY ME WHEN IN STOCK

      Description

      The ODO/T probe assembly pairs with the ProSolo Handheld to form a complete sampling system. Please visit the ProSolo ODO/T Kits page for fully assembled systems.
      • Featuring integral, digital sensors, the ODO/T is plug-and-play which minimizes time spent on instrument setup. ProDIGITAL technology allows the handheld to automatically recognize connected sensors, so there is no need to tell the instrument what is connected. Optical Dissolved Oxygen (ODO) technology is non-consumptive, meaning oxygen is not consumed during the measurement. Flow dependence is non-existent and no stirring is required, resulting in the most accurate DO measurements available from a probe. The ODO sensor is not susceptible to interferences from other gases, drifts less and holds calibration longer than membrane covered sensors. Maintenance is a breeze with a simple, threaded optical cap that is good for at least two years.

        The ProDIGITAL ODO/T probe and cable assembly features include:

        Integral optical dissolved oxygen, and temperature sensors that are auto-recognized by ProDIGITAL handhelds, reducing instrument set-up time
        Rugged Optical DO sensor cap with a 2-year warranty is pre-installed on new assemblies
        Military Spec (MS) connector and a weighted, stainless steel probe guard
        Fits in a 1 inch well with cable lengths up to 100 meters
        2-year warranty on cable, sensors, and ODO cap

        Acuracy

        Temperature - ±0.2 °C

        Dissolved Oxygen - 0 to 200%: ±1% of reading or 1% saturation, whichever is greater 200 to 500%: ±8% of reading 0 to 20 mg/L: ±0.1 mg/L or 1% of reading, whichever is greater 20 to 50 mg/L: ±8% of reading

        Measurement Method / Channels Temperature - Thermistor; Dissolved Oxygen - Optical luminescence - lifetime method
        Measurement Range

        Temperature - -5 to 70 °C (temperature compensation range for DO mg/L measurement: -5 to 50 °C )

        Dissolved Oxygen - 0 to 500%, 0 to 50 mg/L

        Parameters Measured

        Dissolved Oxygen, Temperature

        Size

        Width - 2.46 cm (0.97 in.)

        Unit of Measure Temperature - °C, °F, K; Dissolved Oxygen - % saturation, % saturation local, mg/L, ppm
        Warranty

        Warranty 2-year probe and cable assembly; 2-year extended warranty ODO sensor cap