The Milwaukee CD600 Total Dissolved Solids (TDS) Pen is designed for hydroponics, aquariums, horticulture, water conditioning and many other applications. The CD600 helps you make sure that your plants are receiving the right amount of nutrient or helps you keep your filters up-to-date and clean for water filtration. Keep TDS in your target range to help your achieve better results.
DESIGN FEATURES
Measures Total Disolved (TDS) direct and with automatic temperature compensation.
Ideal range for hydroponics (0 to 1990 ppm).
Units in ppm easily convertable to uS/cm.
Factory calibrated with the ability to recalibrate if needed.
Automatic Temperature Compensation (ATC).
350 hours continuous use (4 x 1.5V batteries included).
Simple one point calibration.
CARE AND USE
MAINTENANCE
TDS/PPM electrodes can develop nutrient build up over time. To miminize build up, always rinse the probe in fresh tap or DI water after every use.
CONVERTING TDS TO EC
The Milwaukee TDS Pen, like all TDS meters, provides a measure of Total Dissolved Solids (ppm) reading, of contaminates per unit of volume in a solution.
TDS/PPM is often converted to uS/cm. Different scales include the 500 scale, 650 scale and the 700 scale.
Your TDS/PPM readings can be approximately converted to uS/cm as shown in the examples below.
1 ppm = 2 uS/cm on the 0.5 factor scale
1 ppm = 1.43 µS/cm on the 442 scale or .70 factor scale
Thank you for considering Milwaukee to help you take your results to the next level.
The Milwaukee CD601 digital electrical conductivity (EC) Pen is designed for aquariums, aquaculture, pools, water conditioning and many other applications. The CD601 helps you make sure that your water has the right amount of nutrient to help keep fish tanks healthy or helps you keep your filters up-to-date and clean for water filtration. Keep EC in your target range to help your achieve better results.
DESIGN FEATURES
Measures microSiemens (uS/cm) direct and with automatic temperature compensation.
Ideal range for aquariums (0 to 1990 uS/cm).
Units in uS/cm are easily convertible to (ppm).
Factory calibrated with the ability to recalibrate if needed.
Automatic Temperature Compensation (ATC).
350 hours continuous use (4 x 1.5V batteries included).
Simple one point calibration.
CARE AND USE
MAINTENANCE
EC electrodes can develop nutrient build up over time. To miminise build up, always rinse the probe in fresh tap or DI water after every use.
CONVERTING EC TO TDS
The Milwaukee EC Pen, like all conductivity meters, provides a measure of electrically charged ions in a solution and is an absolute measure of conductivity.
EC is often converted to TDS in parts per million (ppm). Different scales include the 500 scale, 650 scale and the 700 scale. However, true PPM can only be determined through chemical analysis.
Your mS/cm reading can be approximately converted to TDS (ppm) as shown in the examples below.
2,000 µS/cm = 2.0 mS/cm = 1000 ppm on .50 factor scale
2,000 µS/cm = 2.0 mS/cm = 1400 ppm on the 442 scale or .70 factor scale
Thank you for considering Milwaukee to help you take your results to the next level.
The Milwaukee EC59 PRO Conductivity (EC) & Total Dissolved Solids (TDS) Tester is designed for aquaculture, food, wine, laboratory, water treament and many other applications. It is the ideal meter to help make sure that your EC/TDS/Temp. needs are being met and are reliable results for your analysis. Keep EC/TDS/TEMP. in your target range to help your achieve best results.
DESIGN FEATURES
Measures EC/TDS/Temp. with automatic temperature compensation (ATC).
Ideal range for all different applications (0 to 3999 uS/cm) | 0 to 2000 ppm | 0.0 to 60°C (32.0 to 140.0°F).
Units in uS/cm or ppm easily convertable to other ranges.
Factory calibrated with the ability to recalibrate if needed.
Replaceable electrode Mi59P.
Fully waterproof to IP65.
Approximately 100 hours of use (4 x 1.5V batteries included).
CARE AND USE
MAINTENANCE
EC electrodes can develop nutrient build up over time. To miminize build up, always rinse the probe in fresh tap water after every use.
CONVERTING EC TO TDS
The Milwaukee PRO Conductivity Tester, like all conductivity meters, provides a measure of electrically charged ions in a solution and is an absolute measure of conductivity.
EC/TDS can converted. Different scales include the 500 scale, 650 scale and the 700 scale.
Your uS/cm reading can be approximately converted to other scales as shown in the examples below.
2.00 mS/cm = 2000 uS/cm = 1000 ppm on .50 factor scale
2.00 mS/cm = 2000 uS/cm = 1400 ppm on the 442 scale or .70 factor scale
The Milwaukee EC60 PRO Conductivity Tester is designed for hydroponic and other growers to help you make sure that your plants have the ideal amount of nutrient avaiable. Keep EC in your target range to help your achieve better results.
DESIGN FEATURES
Measures conductivity and TDS with automatic temperature compensation
Ideal range for hydroponic and other growers (0.00 to 20.00 mS/cm)
Units in mS/cm or ppt easily convertible to ppm
Factory calibrated with the ability to recalibrate if needed
Replaceable electrode
Fully waterproof to IP65
Approximately 100 hours of use (4 x 1.5V batteries included)
CARE AND USE
MAINTENANCE
EC electrodes can develop nutrient build up over time. To miminise build up, always rinse the probe in fresh tap water after every use.
CONVERTING EC TO TDS
The Milwaukee EC60 PRO Conductivity Tester, like all conductivity meters, provides a measure of electrically charged ions in a solution and is an absolute measure of conductivity.
In Hydroponics, EC is often converted to TDS in parts per million (ppm). Different scales include the 500 scale, 650 scale and the 700 scale. However, true PPM can only be determined through chemical analysis.
Your mS/cm reading can be approximately converted to TDS (ppm) as shown in the examples below.
2.00 mS/cm = 2000 uS/cm = 1000 ppm on .50 factor scale
2.00 mS/cm = 2000 uS/cm = 1400 ppm on the 442 scale or .70 factor scale
M10004B is a lab grade pH 4.01 buffer solution certified to meet the standard to an accuracy of ±0.01 pH removing the inaccuracies involved with mixing calibration solutions from powder.
Sachet packaging means that you get fresh solution every time. Ideal for infrequent or field use. No risk of using expired calibration solution.
Milwaukee solutions are designed to help you achieve reliable and repeatable pH measurements while extending the life of your electrode.
DESIGN FEATURES
pH 4.01 Calibration Buffer Solution - 20 mL
Fundamental for the correct use of electrodes and for obtaining the most accurate and reproducible readings
Sealed against light and air
Ideal for on-the-spot calibration
Simply open, insert the tester or electrode into the sachet and calibrate
Formulated with a 5 year expiry
Colour coded for easy identification
Probe calibration is a simple procedure for optimal performance and should be done any time your readings become suspect. Calibration should be performed at least once a month.
M10007B is a lab grade pH 7.01 calibration solution certified to meet the standard with an accuracy of ±0.01 pH removing the inaccuracies involved with mixing solutions from powder.
Sachet packaging means that you get fresh solution every time. Ideal for infrequent or field use. No risk of using an expired calibration solution.
Milwaukee solutions are designed to help you achieve reliable and repeatable pH measurements while extending the life of your electrode.
DESIGN FEATURES
pH 7.01 Calibration Buffer Solution - 20 mL
Fundamental for the correct use of electrodes and for obtaining the most accurate and reproducible readings
Sealed against light and air
Ideal for on-the-spot calibration
Simply open, insert the tester or electrode into the sachet and calibrate
Formulated with a 5 year expiry
Colour coded for easy identification
Probe calibration is a simple procedure for optimal performance and should be done any time your readings become suspect. Calibration should be performed at least once a month.
M10010B is a lab grade pH 10.01 calibration solution certified to meet the standard to an accuracy of ±0.01 pH removing the inaccuracies involved with mixing from powder.
Sachet packaging means that you get fresh solution every time. Ideal for infrequent or field use. No risk of using an expired or contaminated solution.
Milwaukee solutions are designed to help you achieve reliable and repeatable pH measurements while extending the life of your electrode.
DESIGN FEATURES
pH 10.01 Calibration Buffer Solution - 20 mL
Fundamental for the correct use of electrodes and for obtaining the most accurate and reproducible readings
Sealed against light and air
Ideal for on-the-spot calibration
Simply open, insert the tester or electrode into the sachet and calibrate
Formulated with a 5 year expiry
Colour coded for easy identification
Electrode cleaning solution is ideal for cleaning all pH, ORP and TDS meter's probes. To help maintain high performance and accuracy for any electrode, regular cleaning is required to remove the build up of dirt and sediment on the glass or carbon surfaces of a sensing probe. Use M10016B to help extend the life of the meter's electrode.
Electrode cleaning solution should not be a substitute for rinse and or storage solutions.
Sachet packaging means that you get fresh solution every time. Ideal for infrequent or field use. No risk of using an expired calibration solution.
Milwaukee cleaning solutions are designed to help you achieve reliable and repeatable measurements while extending the life of your electrode.
DESIGN FEATURES
Electrode Cleaning Solution - 20 mL (box of 25).
Fundamental for gently cleaning the electrode between uses and before storage.
Sealed against light and air.
Ideal for on-the-spot cleaning too.
Simply open, insert the tester or electrode into the sachet and gently stir let soak for 15 minutes.
Formulated with a 5 year expiry