High-Quality Replacement
Milwaukee MA841 Spare Membrane is a top-tier replacement option for dissolved oxygen probes. Made with high-quality materials, this spare membrane ensures accurate readings and long-lasting durability. Whether you're in a lab setting or conducting field work, this replacement membrane is designed to meet all your dissolved oxygen measurement needs.
Easy to Install
Designed for easy installation, the Milwaukee MA841 Spare Membrane can be quickly swapped out with minimal downtime. Simply remove the old membrane from your dissolved oxygen probe and replace it with this new one. With its user-friendly design, you can effortlessly maintain your equipment and keep your measurements precise.
Compatibility and Reliability
This spare membrane is specifically designed to be compatible with Milwaukee's MA841 Dissolved Oxygen Probe. Tested for reliability and accuracy, you can trust that this replacement membrane will deliver consistent performance. Ensure your dissolved oxygen probe continues to work at its best with the Milwaukee MA841 Spare Membrane.
Cobália is an advanced farm management platform that enables you to control and evaluate every part of your production. The farm management system will keep track of daily, monthly and yearly tasks, auto-generate reports for authorities, keep track of inventory and give a complete visual overview of the conditions on your farm.
Optimisation
Management
Price if for a single tag
YSI ODO replacement optical dissolved oxygen screw-on sensor cap.
Overview
Includes screw-on sensor cap and calibration code sequence.
Average life is 1 year or greater.
Response Time (T95 - from 0 to 100%) = 40 seconds Flow Dependence After 4 Minutes = 0% Required Flow Rate = 0 inches/second; non-consumptive optical method
Specifications
Equipment used with
ProODO Probe
YSI 2002 Galvanic Dissolved Oxygen sensor for the Pro Series
OverviewEasy user-replaceble sensor allows for quick sensor replacements if needed. No tools necessary. The 2002 Galvanic Dissolved Oxygen sensor comes with 5913 Cap Membrane Kit (1.25 Mil PE, Polyethylene membranes) for fast response with reliable readings. Convenient screw-on cap membranes make membrane changes simple and easy. Six-month sensor warranty.
CompatibilityThe 2002 Galvanic DO Sensor is compatible with these YSI Handheld Instruments*: • ProQuatro • Pro Plus • Pro20 • Pro20i • Pro1020 • Pro2030 *Requires Cable/Probe Assembly.
Luminescence-based LDO technology - no replacement of electrolyte, no interference by deposits or H2S
Intellical LDO101 is a digital, luminescent/optical dissolved oxygen (LDO) probe. This Rugged DO sensor version is built with a stainless steel body ensuring sufficient weight to the probe for an easy outside handling, the sensing part is protected by a shroud, and the connection is ensured by strong and visible yellow coloured cable onto which you can clip depth markers (optional accessories), making the LDO101 rugged models specially designed for field use. LDO101 Rugged is available with a 5, 10, 15, or 30 meters cable. The LDO101 is fitted with an automatic pressure sensor module and a temperature sensor. LDO101 probes are fully calibrated at the factory. New LDO101 probes no longer require iButtons. The days in use tracking feature and the remaining sensor cap life reminder are initialized on the day of first use. The LDO101 Rugged is ideal for measuring dissolved oxygen in all type of external environment such as river, surface and ground waters, ponds, lakes, sea, wastewater plant, source water, drinking water reservoir for water quality, environmental and treatment process purposes.
Hach Intellical LDO is a revolutionary breakthrough in the measurement of dissolved oxygen, eliminating the numerous reliability and maintenance concerns inherent of older DO measurement technologies.
Intellical Rugged digital probes can reliably test in the harshest environmental conditions
Intellical digital probes provide ultimate traceability in measurement history
Intellical digital probes alert the user when re-calibration is needed
Intellical digital probes can be moved between meters without the need to re-calibrate or re-enter measurement settings
Replacement sensor cap for the LDO101 Series IntelliCALTM probes for use with the HQ meters.Included with each sensor cap are replacement seals and an iButton(R) containing the new calibration codes.
To ensure quality, YSI inspects conductivity solutions with reference to primary standard solutions according to OIML recommendation 56. Bottles include a table of corrections at temperatures between 20 and 30 oC.
For sea water equipment.
Easy CO2 Calibration
The OxyGuard CO2 Calibration Beaker with stirrer magnet is an essential tool for efficiently calibrating CO2 sensors. This beaker allows you to accurately measure and calibrate CO2 levels in your samples, ensuring precise and reliable readings every time. The included stirrer magnet helps to mix the solution evenly, resulting in consistent measurements.
Durable Construction
This calibration beaker is made of high-quality materials that are built to last. Its sturdy construction ensures durability and longevity, making it a reliable tool for your calibration needs. The beaker is also easy to clean, allowing for hassle-free maintenance and care.
Convenient Design
The OxyGuard CO2 Calibration Beaker features a convenient design that makes calibration quick and easy. The clear markings on the beaker make it simple to read and measure CO2 levels accurately. The stirrer magnet provides efficient mixing, saving you time and effort during the calibration process. With its user-friendly design, this beaker is a must-have tool for any lab or research facility.
The ODO/CT, probe and cable assembly features integral (i.e., built-in) optical dissolved oxygen, conductivity, and temperature sensors and is available in lengths up to 100 meters. It’s perfect for measuring DO in the following applications – estuary, wetland, coastal, aquaculture, or any application requiring accurate, real-time salinity-compensated DO measurements.
The ODO/CT assembly is compatible with the ProSolo, ProSwap, and ProDSS handhelds (sold separately). Pre-assembled ProSolo kits are available
The ODO/CT has all the advantages of optical dissolved oxygen technology – higher accuracy, less maintenance, no stirring required for accurate measurements, holds calibration longer than membrane covered sensors and is not susceptible to interferences from other gases.
Instrument setup is quick and easy with the integral sensors, which eliminates the need to install sensors before use. The digital technology of the ProDSS allows the handheld to automatically recognize connected sensors, so there is no need to tell the instrument what is connected.
The ProDIGITAL ODO/CT probe and cable assembly features include:
Integral (i.e. built-in) optical DO, conductivity, and temperature sensors that are auto-recognized by Pro Series handhelds, reducing instrument set-up time
Automatically compensates DO mg/L measurements for salinity; no need to enter salinity compensation values
Rugged Optical DO sensor cap with a 2-year warranty is pre-installed on new assemblies
Fits in a 1 inch well
Easy user-replaceable sensor allows for quick sensor replacements, if needed.
Quickly switch DO sensors without having to send in the instrument for repair or replacing the entire cable assembly.
One-year sensor warranty.
Uses convenient screw-on cap membranes making membrane changes simple and easy.
A range of conductivity probes for use with the hach HQ14, HQ30 and HQ40 meter rangesSpecification Details (Probe models: CDC40101, CDC40103, CDC40105, CDC40110,CDC40115, CDC40130)
Conductivity range 0.01 μS/cm to 200.0 mS/cm
K= 0.40 ± 10%
Conductivity resolution 0.0 to 19.99 μS/cm: 0.01 μS/cm, 20.0 to 199.9 μS/cm: 0.1 μS/cm, 200 to 1999 μS/cm: 1 μS/cm, 2.00 to 19.99 mS/cm: 0.01 mS/cm, 20.0 to 200.0 mS/cm: 0.1 mS/cm
Conductivity accuracy ± 0.5% of reading
TDS range 0 to 50,000 mg/L as NaCl
TDS accuracy ± 0.5% of reading
TDS resolution 0.0 to 19.99 mg/L: 0.01 mg/L, 200 to 1999 mg/L: 1 mg/L, 2.00 to 19.99 g/L: 0.01 g/L, 20.0 to 50.0 g/L: 0.1 g/L
Salinity range 0 to 42 (ppt) (€°)
Salinity accuracy ± 1 parts per thousand (ppt) (€°)
Salinity resolution 0.01 parts per thousand (ppt) (€°)
Temperature range -10.0 to 110.0 °C (14 to 230 °F)
Storage temperature 0 to 40 °C (32 to 104 °F)
Temperature accuracy ± 0.3 °C (± 1.09 °F)
Minimum sample depth 45 mm (1.77 in.)
Dimensions Diameter: 14 mm (0.55 in.), Length: 103 mm (4.06 in.), Total length: 220 mm (8.66 in.)
Cable length (standard): 1 or 3 meter (3.28 or 9.84 ft)
Cable length (rugged): 5, 10, 15 or 30 meter (16.4, 32.8, 49.2, or 98.4 ft)
Cable connection Digital output and connector compatible with HQd range meters
Effective Sensor Calibration
Ensure accurate CO2 measurements with our Calibration Solution for OxyGuard sensors. This solution is specifically designed to calibrate OxyGuard CO2 sensors, providing reliable and precise readings for your monitoring system. By calibrating your sensors regularly with our solution, you can trust that your data is accurate and actionable.
Convenient to Use
Our Calibration Solution is easy to use, making the calibration process quick and efficient. Simply follow the instructions provided with the solution to calibrate your OxyGuard CO2 sensors with ease. With this convenient solution, you can maintain the performance of your sensors without any hassle, ensuring optimal functionality at all times.
Reliable Performance
Trust in the reliability of our Calibration Solution to keep your OxyGuard CO2 sensors in top working condition. Our solution is formulated to deliver consistent and dependable results, allowing you to monitor CO2 levels accurately and effectively. With our Calibration Solution, you can have peace of mind knowing that your sensors are performing at their best.
Easily manage your longer cables. Automatically included with Pro Series cables 4-meters and longer. Also attaches to the back of the instrument to create a very compact system. Ideal for 4-, 10-, 20-, and 30-meter cables.
YSI 5913 screw-on cap dissolved oxygen membranes for 2002 Galvanic sensors
Includes bottle of NaCl electrolyte, 1 sanding disc, and 6 screw-on cap membranes. 1.25 Mil PE, Polyethylene membrane {Yellow cap). Convenient scew-on cap membranes make membrane changes simple and easy. Response Time (T95 - from 0 to 100%) = 8 seconds Flow Dependence After 4 Minutes = 25% Required Flow Rate = 6 inches/ second.