Milwaukee


  • Milwaukee CD600 Digital Total Dissolved Solids Pen (TDS) Pocket Tester Milwaukee

    Milwaukee Milwaukee CD600 Digital Total Dissolved Solids Pen (TDS)

    The Milwaukee CD600 Total Dissolved Solids (TDS) Pen is designed for hydroponics, aquariums, horticulture, water conditioning and many other applications. The CD600 helps you make sure that your plants are receiving the right amount of nutrient or helps you keep your filters up-to-date and clean for water filtration. Keep TDS in your target range to help your achieve better results. DESIGN FEATURES Measures Total Disolved (TDS) direct and with automatic temperature compensation. Ideal range for hydroponics (0 to 1990 ppm). Units in ppm easily convertable to uS/cm. Factory calibrated with the ability to recalibrate if needed. Automatic Temperature Compensation (ATC). 350 hours continuous use (4 x 1.5V batteries included). Simple one point calibration. CARE AND USE MAINTENANCE TDS/PPM electrodes can develop nutrient build up over time. To miminize build up, always rinse the probe in fresh tap or DI water after every use. CONVERTING TDS TO EC The Milwaukee TDS Pen, like all TDS meters, provides a measure of Total Dissolved Solids (ppm) reading, of contaminates per unit of volume in a solution. TDS/PPM is often converted to uS/cm. Different scales include the 500 scale, 650 scale and the 700 scale. Your TDS/PPM readings can be approximately converted to uS/cm as shown in the examples below. 1 ppm = 2 uS/cm on the 0.5 factor scale 1 ppm = 1.43 µS/cm on the 442 scale or .70 factor scale Thank you for considering Milwaukee to help you take your results to the next level.

    £15.24

  • Milwaukee CD601 Digital Conductivity Pen (EC) Pocket Tester Milwaukee

    Milwaukee Milwaukee CD601 Digital Conductivity Pen (EC)

    The Milwaukee CD601 digital electrical conductivity (EC) Pen is designed for aquariums, aquaculture, pools, water conditioning and many other applications. The CD601 helps you make sure that your water has the right amount of nutrient to help keep fish tanks healthy or helps you keep your filters up-to-date and clean for water filtration. Keep EC in your target range to help your achieve better results. DESIGN FEATURES Measures microSiemens (uS/cm) direct and with automatic temperature compensation. Ideal range for aquariums (0 to 1990 uS/cm). Units in uS/cm are easily convertible to (ppm). Factory calibrated with the ability to recalibrate if needed. Automatic Temperature Compensation (ATC). 350 hours continuous use (4 x 1.5V batteries included). Simple one point calibration. CARE AND USE MAINTENANCE EC electrodes can develop nutrient build up over time. To miminise build up, always rinse the probe in fresh tap or DI water after every use. CONVERTING EC TO TDS The Milwaukee EC Pen, like all conductivity meters, provides a measure of electrically charged ions in a solution and is an absolute measure of conductivity. EC is often converted to TDS in parts per million (ppm). Different scales include the 500 scale, 650 scale and the 700 scale. However, true PPM can only be determined through chemical analysis. Your mS/cm reading can be approximately converted to TDS (ppm) as shown in the examples below. 2,000 µS/cm = 2.0 mS/cm = 1000 ppm on .50 factor scale 2,000 µS/cm = 2.0 mS/cm = 1400 ppm on the 442 scale or .70 factor scale Thank you for considering Milwaukee to help you take your results to the next level.

    £13.43

  • Milwaukee M10031B 1413 µS/cm Conductivity Calibration Solution Sachet Sachet Milwaukee

    Milwaukee Milwaukee M10031B 1413 µS/cm Conductivity Calibration Solution Sachet

    The performance of conductivity probes are affected by use due to residue build up and aging.  M10031B is a lab grade 1413 µS/cm conductivity solution standard prepared against a NIST traceable potassium chloride solution that allows you to recalibrate your conductivity meter or tester. Check your meter or tester's manual to find the correct calibration standard for your meter. Conductivity readings are effected by temperature. To help with this, a chart of the actual µS/cm value at various temperatures is printed on each sachet. Milwaukee conductivity solutions are labeled with the lot number and expiration date and packaged in an air tight, tamper-proof sachet. Design Features Fundamental for accurate conductivity measurement. Factory calibrated with potassium chloride NIST 2202 SRM (Standard Reference Material) in deionized water for analytical use in accordance with ISO 3696/BS3978. Sealed against light and air. Ideal for on-the-spot calibration Simply open, insert the tester or electrode into the sachet and calibrate Each 20 mL sachet is marked with lot number and expiration date. A temperature chart of the actual µS/cm value at various temperatures is printed on each sachet. 5 year expiry date.

    £0.74

  • Last stock! Milwaukee MA9071 Oxygen Electrolyte Solution Accessory Milwaukee

    Milwaukee Milwaukee MA9071 Oxygen Electrolyte Solution

    The MA9071 electrolyte fill solution is designed for Milwaukee's polarographic dissolved oxygen probe. A high quality electrolyte solution is crucial to the performance of your dissolved oxygen probe. DESIGN FEATURES PRECISE FORMULATION Factory mixed using reagent grade chemicals in a dedicated, temperature controlled environment. TRACEABLE Product labeled with product code, lot number and expiration date. SECURE Air tight bottle with tamper-proof seal. USE AND CARE “OPEN AIR” CALIBRATION PROCEDURE FOR THE MW600 DISSOLVED OXYGEN METER 1. Remove the membrane Take the membrane off the end of the probe and dry the diode off. 2. Zero out the display Connect the probe to the base unit and turn the unit on. Your display should read 0.0. If it does not, go to the position “0” screw on the front of the unit with the screw driver provided and through the access hole make the unit display read 0.0. 3. Fill the membrane Go to the membrane and put the “O” ring inside the membrane on the shoulder at the base of the threads. Fill the membrane to just short of the “O” ring with MA9071 electrolyte solution. Be sure that there are no bubbles inside the membrane. (Air bubbles are the main cause of calibration failure) 4. Attach the membrane Screw the membrane on to the probe. 5. Let stabilize Turn the meter on and hang the probe off the end of a table pointing down and let the unit display stabilize (this may take 5 to 15 minutes) 6. Adjust Push down and hold the “Cal” button on the front face of the meter and with the screwdriver go to the front Cal position “100%” and make the display read 100. You are now calibrated. EXTRA TIPS Watch for the membrane having wrinkles or stretch marks. If you see wrinkles, replace with a new membrane. Always use fresh electrolyte solution (MA9071).

    £22.72

  • Milwaukee MA9016 Cleaning Solution for pH / ORP Electrodes Accessory Milwaukee

    Milwaukee Milwaukee MA9016 Cleaning Solution for pH / ORP Electrodes

    MA9016 is a lab grade electrode cleaning solution prepared with premium chemicals to improve the performance and extend the life of your pH and ORP electrodes, testers and pens. Your accuracy and speed of your results are dependent on your pH sensing bulb and ORP platinum tip being clean. pH and ORP electrodes also need a free flowing junction to function. Milwaukee's cleaning solution helps both keep sensing parts clean and the junction open. Simply open the bottle, fill a beaker or container so that the level covers the sensor and junction, and soak for 15 to 20 minutes followed by a soaking in MA9015 storage solution for at least 2 hours. DESIGN FEATURES Fundamental for the correct use of electrodes and for obtaining the most accurate and reproducible readings. Specially formulated for cleaning electrodes Factory blended to precise standards in a dedicated, temperature controlled environment. Sealed against light with air tight, tamper proof cap. Each bottle marked with lot number and expiration date.

    £10.10

  • Milwaukee T75 Waterproof Low Range Total Dissolved Solids Pen (TDS) Handheld Meter Milwaukee

    Milwaukee Milwaukee T75 Waterproof Low Range Total Dissolved Solids Pen (TDS)

    The Milwaukee T75 Waterproof Total Dissolved Solids (TDS) Pen is designed for, aquariums, aquaculture, education, water conditioning and many other applications. The T75 helps you make sure that your fish have the right TDS balance to help them stay healthy. TDS also help keep filters up-to-date and clean for water filtration. Keep TDS in your target range to help your achieve better results. DESIGN FEATURES Measures Total Disolved (TDS) direct and with automatic temperature compensation. Easy-to-read LCD. Ideal range for aquariums (0 to 1999 ppm). Units in ppm easily convertible to uS/cm. Factory calibrated with the ability to recalibrate if needed. 250 hours continuous use (3 x 1.5V batteries included). Simple one point calibration. Fully waterproof to IP65 Replaceable TDS electrode MA73075. CARE AND USE MAINTENANCE TDS/PPM electrodes can develop nutrient build up over time. To miminice build up, always rinse the probe in fresh tap or DI water after every use. CONVERTING TDS TO EC The Milwaukee TDS Pen, like all TDS meters, provides a measure of Total Dissolved Solids (ppm) reading, of contaminates per unit of volume in a solution. TDS/PPM is often converted to uS/cm. Different scales include the 500 scale, 650 scale and the 700 scale. Your TDS/PPM readings can be approximately converted to uS/cm as shown in the examples below. 1 ppm = 2 uS/cm on the 0.5 factor scale 1 ppm = 1.43 µS/cm on the 442 scale or .70 factor scale Thank you for considering Milwaukee to help you take your results to the next level.

    £21.92

  • Milwaukee M10032B 1382 ppm TDS Calibration Solution Sachet Sachet Milwaukee

    Milwaukee Milwaukee M10032B 1382 ppm TDS Calibration Solution Sachet

    The performance of conductivity probes are affected by use due to residue build up and aging. M10032B is a lab grade 1382 ppm TDS solution standard prepared against a NIST traceable potassium chloride solution that allows you to recalibrate your conductivity meter or tester. Check your meter or tester's manual to find the correct calibration standard for your meter. TDS readings are effected by temperature. To help with this, a chart of the actual ppm value at various temperatures is printed on each sachet. Milwaukee TDS solutions are labelled with the lot number and expiration date and packaged in an air tight, tamper-proof sachet. DESIGN FEATURES Fundamental for accurate TDS measurement. Factory calibrated with potassium chloride NIST 2202 SRM (Standard Reference Material) in deionized water for analytical use in accordance with ISO 3696/BS3978. Sealed against light and air. Ideal for on-the-spot calibration Simply open, insert the tester or electrode into the sachet and calibrate Each 20 mL sachet is marked with lot number and expiration date. A temperature chart of the actual ppm value at various temperatures is printed on each sachet. 5 year expiry date.

    £0.74

  • Milwaukee M10030B 12880 µS/cm Conductivity Calibration Solution Sachet Sachet Milwaukee

    Milwaukee Milwaukee M10030B 12880 µS/cm Conductivity Calibration Solution Sachet

    The performance of conductivity probes are affected by use due to residue build up and aging.  M10030 is a lab grade 12880 µS/cm conductivity solution standard prepared against a NIST traceable potassium chloride solution that allows you to recalibrate your conductivity meter or tester. Check your meter or tester's manual to find the correct calibration standard for your meter. Conductivity readings are effected by temperature. To help with this, a chart of the actual µS/cm value at various temperatures is printed on each sachet. Milwaukee conductivity solutions are labeled with the lot number and expiration date and packaged in an air tight, tamper-proof sachet. Design Features Fundamental for accurate conductivity measurement. Factory calibrated with potassium chloride NIST 2202 SRM (Standard Reference Material) in deionized water for analytical use in accordance with ISO 3696/BS3978. Sealed against light and air. Ideal for on-the-spot calibration Simply open, insert the tester or electrode into the sachet and calibrate Each 20 mL sachet is marked with lot number and expiration date. A temperature chart of the actual µS/cm value at various temperatures is printed on each sachet. 5 year expiry date.

    £0.74

  • 25pk Milwaukee M10010B pH 10.01 Calibration Solution Sachet Accessory Milwaukee

    Milwaukee 25pk Milwaukee M10010B pH 10.01 Calibration Solution Sachet

    Probe calibration is a simple procedure for optimal performance and should be done any time your readings become suspect. Calibration should be performed at least once a month. M10010B is a lab grade pH 10.01 calibration solution certified to meet the standard to an accuracy of ±0.01 pH removing the inaccuracies involved with mixing from powder. Sachet packaging means that you get fresh solution every time. Ideal for infrequent or field use. No risk of using an expired or contaminated solution. Milwaukee solutions are designed to help you achieve reliable and repeatable pH measurements while extending the life of your electrode. DESIGN FEATURES pH 10.01 Calibration Buffer Solution - 20 mL Fundamental for the correct use of electrodes and for obtaining the most accurate and reproducible readings Sealed against light and air Ideal for on-the-spot calibration Simply open, insert the tester or electrode into the sachet and calibrate Formulated with a 5 year expiry Colour coded for easy identification

    £14.99

  • 25pk Milwaukee M10007B pH 7.01 Calibration Solution Sachet Accessory Milwaukee

    Milwaukee 25pk Milwaukee M10007B pH 7.01 Calibration Solution Sachet

    Probe calibration is a simple procedure for optimal performance and should be done any time your readings become suspect. Calibration should be performed at least once a month. M10007B is a lab grade pH 7.01 calibration solution certified to meet the standard with an accuracy of ±0.01 pH removing the inaccuracies involved with mixing solutions from powder. Sachet packaging means that you get fresh solution every time. Ideal for infrequent or field use. No risk of using an expired calibration solution. Milwaukee solutions are designed to help you achieve reliable and repeatable pH measurements while extending the life of your electrode. DESIGN FEATURES pH 7.01 Calibration Buffer Solution - 20 mL Fundamental for the correct use of electrodes and for obtaining the most accurate and reproducible readings Sealed against light and air Ideal for on-the-spot calibration Simply open, insert the tester or electrode into the sachet and calibrate Formulated with a 5 year expiry Colour coded for easy identification

    £14.99

  • Last stock! 25pk Milwaukee M10004B pH 4.01 Calibration Solution Sachet Accessory Milwaukee

    Milwaukee 25pk Milwaukee M10004B pH 4.01 Calibration Solution Sachet

    M10004B is a lab grade pH 4.01 buffer solution certified to meet the standard to an accuracy of ±0.01 pH removing the inaccuracies involved with mixing calibration solutions from powder. Sachet packaging means that you get fresh solution every time. Ideal for infrequent or field use. No risk of using expired calibration solution. Milwaukee solutions are designed to help you achieve reliable and repeatable pH measurements while extending the life of your electrode. DESIGN FEATURES pH 4.01 Calibration Buffer Solution - 20 mL Fundamental for the correct use of electrodes and for obtaining the most accurate and reproducible readings Sealed against light and air Ideal for on-the-spot calibration Simply open, insert the tester or electrode into the sachet and calibrate Formulated with a 5 year expiry Colour coded for easy identification

    £14.99

  • Milwaukee MA9020 ORP 200-275 mV Solution Accessory Milwaukee

    Milwaukee Milwaukee MA9020 ORP 200-275 mV Solution

    MA9020 is a lab grade ORP 200-275 mV solution certified to meet the range. MA9020 is used to check the health and accuracy of an ORP electrode. Milwaukee solutions are designed to help you achieve reliable and repeatable ORP measurements. DESIGN FEATURES OPR 200-275 mV solution value (230 mL). Fundamental for the correct use of ORP electrodes and for obtaining the most accurate and reproducible readings. Sealed against light with air tight, tamper proof cap. Ideal for fast accuracy check. Simply open, pour into a beaker or container and insert the tester or electrode to start the ORP mV check process.

    £13.99


© 2024 GroAqua, Powered by Shopify

    • American Express
    • Apple Pay
    • Diners Club
    • Discover
    • Google Pay
    • Maestro
    • Mastercard
    • PayPal
    • Shop Pay
    • Union Pay
    • Visa

    Login

    Forgot your password?

    Don't have an account yet?
    Create account