The Milwaukee MW803 MAX Waterproof Low Range 4-in-1 pH/EC/TDS/Temp Tester is designed as an all-in-one solution for growers.
The Milwaukee MW803 MAX Waterproof 4-in-1 Tester offers:
ACCURACY
The MW803 MAX 4-in-1 tester is accurate to ±0.05 pH, EC/TDS to 2% Full Scale and ±0.5°C / ±1°F for temperature.
With automatic calibration and 5 memorized calibration points, the tester can be quickly and easily be calibrated to a higher accuracy compared with manual calibration.
LONG LIFE
The tester comes with a replaceable pH probe with a double junction probe design for longer life.
FAST RESPONSE
An exposed temperature probe is located close to the pH probe for fast temperature compensation.
WATERPROOF CONSTRUCTION
No more worries about dropping your tester while measuring. The MW803 is fully waterproof to IP65.
LIGHT WEIGHT
At just 3.5 ounces, the MW803 MAX is easy to handle at up to half the weight of other testers.
EASE-OF-USE
A large dual level LCD screen makes reading results easy while a stability indicator and hold function that freezes the display takes the guess work out.
DESIGN FEATURES
Fast easy to read results with large digital dual LCD readout.
Extreme accuracy to ±0.05 pH, EC / TDS 2% Full Scale and Temperature ±0.5 C / ±1 F.
Range 0.00 – 14.00 pH | EC 0 to 3999 uS/cm | TDS 0 - 2000 ppm | Temperature: 0.0 to 50.0 C / 32.0 to 122.0 F.
Lightweight and portable at just 3.5 ounces.
Easy measurement: just place the probe in the sample, gently stir, wait for the stability indication to show a stable reading and then freeze the reading.
Simple push button, automatic 1 or 2 point pH calibration with 5 saved calibration points and simple 1 point EC calibration.
Gel-filled, double junction pH electrode for low maintenance and high performance with exposed temp. sensor for fast readings.
Auto shut off after 8 minutes of non-use.
Fully waterproof to IP65.
Battery life approx. 100 hour of continuous use (batteries included).
CARE AND USE
The MW803 PRO Tester includes both a pH and EC electrode. Both need maintenance.
All pH sensors have a limited life and response time gets longer with age. Properly maintaining your pH pen tester will give you fast, accurate results for longer. So, be sure to order the Milwaukee pH Maintenance Kit code PH-Main at checkout time! This will be needed to help clean and condition the pH electrode before use!
EC sensors are more robust but can still be affected by residue build up.
Here are our top four tips.
1. Always store with the cap full of buffer or storage solution MA9015 not water.
2. Clean your Tester regularly by soaking in cleaning solution MA9016.
3. Calibrate after cleaning and/or storage before testing to adjust for changes in the pH and EC sensor.
4. Gently stir the PRO Tester in the sample for a faster result.
5. Rinse in water after every test.
Thank you for considering Milwaukee to help you take your results to the next level.
This Milwaukee 3-in-1 Low Range combo meter allows you to measure pH, EC (conductivity) and TDS with a single meter and one single probe.
WHAT PEOPLE ARE SAYING
"Superb meter, easy to use, great customer service."
"Best meter I have ever owned."
"The best meter on the market and Milwaukee customer service is the best."
"I have owned this meter for almost 8 years and only replaced the probe once. The calibration nobs are easy to use, and even when I am less then gentle with the thing it keeps on going. I wouldn't consider any other meter."
"Easy calibration features."
"Light weight and ergonomic."
SUMMARY
pH and TDS are critical for water conditioning and aquariums. Total Dissolved Solids in drinking water can effect clarity and taste of water. In addition, high TDS levels can effect the health of a fish in an aquarium. High concentrations of TDS can decrease clarity of water in aquariums and decrease photosynthesis in aquatic plants.
The Milwaukee MW801 PRO Low Range Combo Meter lets you easily and accurately test pH, conductivity and total dissolved solids (TDS) using a single meter and integrated probe.
Simple, portable and rugged. No more juggling multiple electrodes and wires. Automatic temperature compensaton included.
The MW801 is the ultimate solution for pH and nutrient management.
DESIGN FEATURES
The design of the MW801 is focused on simple operation and ruggedness. With a single probe, big screen, easy calibration, the MW801 is exceptionally simple to operate.
A tough meter build and a rugged but replaceable probe means that you can expect years of use.
The Milwaukee PRO Combo meter offers:
pH, conductivity / nutrient EC, TDS (ppm) with automatic temperature compensation.
A replaceable, integrated pH, EC, and TDS (ppm) probe with a single 3 foot cable for easy use (SE600 probe included).
A fiber junction on the pH sensor to reduce contamination when measuring fertilizer solutions.
A light weight and portable form factor at just 5.8 ounces with battery and just over 3 inches wide.
A large easy to read display.
Factory calibration with a simple, single point manual calibration for both pH and EC.
A reputation for a rugged build and long life
Specialized design for drinking water, aquaponic, and aquariums.
CARE AND USE
The MW801 PRO Combo Meter includes both a pH and EC sensor in the SE600 integrated probe. All pH sensors have a limited life and response time gets longer with age. EC sensors are more robust but can still be affected by residue build up. Both need maintenance. Properly maintaining your probe will give you fast, accurate results for longer. So, be sure to order the Milwaukee pH Maitenance Kit code PH-Main at checkout time! This will be needed to help clean and condition the pH/EC electrode before use!
Here are our top four tips.
1. Always store with the cap full of buffer or storage solution not water.
2. Clean your probe regularly by soaking in cleaning solution.
3. Calibrate after cleaning and/or storage before testing to adjust for changes in the pH and EC sensor.
4. Gently stir the probe in the sample for a faster result.
Thank you for considering Milwaukee to help you take your results to the next level.
The Milwaukee CD601 digital electrical conductivity (EC) Pen is designed for aquariums, aquaculture, pools, water conditioning and many other applications. The CD601 helps you make sure that your water has the right amount of nutrient to help keep fish tanks healthy or helps you keep your filters up-to-date and clean for water filtration. Keep EC in your target range to help your achieve better results.
DESIGN FEATURES
Measures microSiemens (uS/cm) direct and with automatic temperature compensation.
Ideal range for aquariums (0 to 1990 uS/cm).
Units in uS/cm are easily convertible to (ppm).
Factory calibrated with the ability to recalibrate if needed.
Automatic Temperature Compensation (ATC).
350 hours continuous use (4 x 1.5V batteries included).
Simple one point calibration.
CARE AND USE
MAINTENANCE
EC electrodes can develop nutrient build up over time. To miminise build up, always rinse the probe in fresh tap or DI water after every use.
CONVERTING EC TO TDS
The Milwaukee EC Pen, like all conductivity meters, provides a measure of electrically charged ions in a solution and is an absolute measure of conductivity.
EC is often converted to TDS in parts per million (ppm). Different scales include the 500 scale, 650 scale and the 700 scale. However, true PPM can only be determined through chemical analysis.
Your mS/cm reading can be approximately converted to TDS (ppm) as shown in the examples below.
2,000 µS/cm = 2.0 mS/cm = 1000 ppm on .50 factor scale
2,000 µS/cm = 2.0 mS/cm = 1400 ppm on the 442 scale or .70 factor scale
Thank you for considering Milwaukee to help you take your results to the next level.
The Milwaukee MW600 PRO Portable Dissolved Oxygen meter is one of Milwaukee's most popular meters with its reliable and fast operation as well as its accuracy.
The Milwaukee PRO DO Meter is preferred by people looking for lab level accuracy without the cost. The Milwaukee DO Meter is popular with everyone from field biologists and educators to fish farmers and koi pond owners.
DESIGN FEATURES
Fast, easy-to-read results with large digital LCD readout
Repeatable, accuracy to ±1.5% FS
Lightweight and portable
Simple 2 point open air calibration (see video below)
Uses MA840 reinforced polarographic probe with an oxygen-permeable polytetrafluorethylene (PTFE) membrane sensor
5 O-rings, membranes and one protective cap included
10 feet probe cable for extra flexibility when testing
70 hours of battery life with continuous use (battery included) with low battery warning
CARE AND USE
“OPEN AIR” CALIBRATION PROCEDURE
1. Remove the membrane
Take the membrane off the end of the probe and dry the diode off.
2. Zero out the display
Connect the probe to the base unit and turn the unit on. Your display should read 0.0. If it does not, go to the position “0” screw on the front of the unit with the screw driver provided and through the access hole make the unit display read 0.0.
3. Fill the membrane
Go to the membrane and put the “O” ring inside the membrane on the shoulder at the base of the threads. Fill the membrane to just short of the “O” ring with MA9071 electrolyte solution. Be sure that there are no bubbles inside the membrane. (Air bubbles are the main cause of calibration failure)
4. Attach the membrane
Screw the membrane on to the probe.
5. Let stablize
Turn the meter on and hang the probe off the end of a table pointing down and let the unit display stabilize (this may take 5 to 15 minutes)
6. Adjust
Push down and hold the “Cal” button on the front face of the meter and with the screwdriver go to the front Cal position “100%” and make the display read 100.
You are now calibrated.
EXTRA TIPS
Watch for the membrane having wrinkles or stretch marks. If you see wrinkles, replace with a new membrane.
Always use fresh electrolyte solution (MA9071).
DOWNLOAD EXCEL WORKSHEET FOR TEMPERATURE COMPENSATION ON MW600 DO METER (XLS)
Determine water temperature, insert reading from meter display, and this worksheet will automatically calculate a temperature-compensated DO reading for you.
M10004B is a lab grade pH 4.01 buffer solution certified to meet the standard to an accuracy of ±0.01 pH removing the inaccuracies involved with mixing calibration solutions from powder.
Sachet packaging means that you get fresh solution every time. Ideal for infrequent or field use. No risk of using expired calibration solution.
Milwaukee solutions are designed to help you achieve reliable and repeatable pH measurements while extending the life of your electrode.
DESIGN FEATURES
pH 4.01 Calibration Buffer Solution - 20 mL
Fundamental for the correct use of electrodes and for obtaining the most accurate and reproducible readings
Sealed against light and air
Ideal for on-the-spot calibration
Simply open, insert the tester or electrode into the sachet and calibrate
Formulated with a 5 year expiry
Colour coded for easy identification
The Milwaukee MW600 PRO Portable Dissolved Oxygen meter is one of Milwaukee's most popular meters with its reliable and fast operation as well as its accuracy.
The Milwaukee PRO DO Meter is preferred by people looking for lab level accuracy without the cost. The Milwaukee DO Meter is popular with everyone from field biologists and educators to fish farmers and koi pond owners.
DESIGN FEATURES
Fast, easy-to-read results with large digital LCD readout
Repeatable, accuracy to ±1.5% FS
Lightweight and portable
Simple 2 point open air calibration (see video below)
Uses MA840 reinforced polarographic probe with an oxygen-permeable polytetrafluorethylene (PTFE) membrane sensor
5 O-rings, membranes and one protective cap included
10 feet probe cable for extra flexibility when testing
70 hours of battery life with continuous use (battery included) with low battery warning
CARE AND USE
“OPEN AIR” CALIBRATION PROCEDURE
1. Remove the membrane
Take the membrane off the end of the probe and dry the diode off.
2. Zero out the display
Connect the probe to the base unit and turn the unit on. Your display should read 0.0. If it does not, go to the position “0” screw on the front of the unit with the screw driver provided and through the access hole make the unit display read 0.0.
3. Fill the membrane
Go to the membrane and put the “O” ring inside the membrane on the shoulder at the base of the threads. Fill the membrane to just short of the “O” ring with MA9071 electrolyte solution. Be sure that there are no bubbles inside the membrane. (Air bubbles are the main cause of calibration failure)
4. Attach the membrane
Screw the membrane on to the probe.
5. Let stablize
Turn the meter on and hang the probe off the end of a table pointing down and let the unit display stabilize (this may take 5 to 15 minutes)
6. Adjust
Push down and hold the “Cal” button on the front face of the meter and with the screwdriver go to the front Cal position “100%” and make the display read 100.
You are now calibrated.
EXTRA TIPS
Watch for the membrane having wrinkles or stretch marks. If you see wrinkles, replace with a new membrane.
Always use fresh electrolyte solution (MA9071).
DOWNLOAD EXCEL WORKSHEET FOR TEMPERATURE COMPENSATION ON MW600 DO METER (XLS)
Determine water temperature, insert reading from meter display, and this worksheet will automatically calculate a temperature-compensated DO reading for you.
The performance of conductivity probes are affected by use due to residue build up and aging. M10030 is a lab grade 12880 µS/cm conductivity solution standard prepared against a NIST traceable potassium chloride solution that allows you to recalibrate your conductivity meter or tester. Check your meter or tester's manual to find the correct calibration standard for your meter. Conductivity readings are effected by temperature. To help with this, a chart of the actual µS/cm value at various temperatures is printed on each sachet. Milwaukee conductivity solutions are labeled with the lot number and expiration date and packaged in an air tight, tamper-proof sachet. Design Features Fundamental for accurate conductivity measurement. Factory calibrated with potassium chloride NIST 2202 SRM (Standard Reference Material) in deionized water for analytical use in accordance with ISO 3696/BS3978. Sealed against light and air. Ideal for on-the-spot calibration Simply open, insert the tester or electrode into the sachet and calibrate Each 20 mL sachet is marked with lot number and expiration date. A temperature chart of the actual µS/cm value at various temperatures is printed on each sachet. 5 year expiry date.
The Milwaukee MW11 Total Chlorine Photometer lets you go digital with your testing. No more hit and miss testing with strips. Great for aquariums, aquaculture & coral, labs, water conditioning , classroom and more. This meter is also ideal for educators that want their students to learn the basics of water quality analysis to apply in the real world.
Simply add the reagent and get a digital reading accurate to ±0.03 ppm within minutes.
DESIGN FEATURES
Fast, easy-to-read results with large digital LCD readout.
Range from 0.00 to 3.50 ppm.
Accurate to ±0.03 ppm or ±3% of reading @ 25 °C.
Small and ergonomic design.
No calibration needed.
Reliable and repeatable measurements with no visual assessment.
Runs on 1 x AAA battery with auto shut off to extend battery life.
Adaptation of the USEPA Method 330.5. The reaction between Free Clorine and DPD causes a slight pink tint in the sample.
Thank you for considering Milwaukee to help you take your results to the next level.
Probe calibration is a simple procedure for optimal performance and should be done any time your readings become suspect. Calibration should be performed at least once a month.
M10010B is a lab grade pH 10.01 calibration solution certified to meet the standard to an accuracy of ±0.01 pH removing the inaccuracies involved with mixing from powder.
Sachet packaging means that you get fresh solution every time. Ideal for infrequent or field use. No risk of using an expired or contaminated solution.
Milwaukee solutions are designed to help you achieve reliable and repeatable pH measurements while extending the life of your electrode.
DESIGN FEATURES
pH 10.01 Calibration Buffer Solution - 20 mL
Fundamental for the correct use of electrodes and for obtaining the most accurate and reproducible readings
Sealed against light and air
Ideal for on-the-spot calibration
Simply open, insert the tester or electrode into the sachet and calibrate
Formulated with a 5 year expiry
Colour coded for easy identification
DIGITAL. SIMPLE. COMPACT.
Thousands of people have relied on the Milwaukee TH300 compact Digital Temperature Meter to read temperature in difficult areas with it's flexible 1 meter cable and stainless steel probe. The durable, digital readout is fast and accuracte and best of all is environmentally friendly with NO mercury, NO glass. From fish tanks to breweries and wineries the TH300 is your quick temperature meter.
SUMMARY
The Milwaukee TH300 compact digital thermometer is specifically designed to help professionals and home owners regulate their pools, wine process, classroom experminents or labs duties. Keeping the proper temperature improves results of beer and wine output. It also helps in understanding the quality of lab data. Keep temperature in your target range for better results.
WHAT PEOPLE ARE SAYING
"Accurate results and calibrated right out of the box."
"Must have for any aquarium owner."
"Good value. Easy to use. Consistent."
"No dangerous chemicals"
"Used it in the field for checking the fruit to harvest, was great"
DESIGN FEATURES
Fast, accurate results with large digital LCD readout.
Extended temperature range: -50 to 150°C (-58 to 302°F)
Easy measurement: just place the stainless steel probe in the sample and wait for the reading to stabilize.
Easy, flexible 1 meter cable for hard to reach places.
Stainless Steel pointed probe for easy fruit penetration and easy cleaning.
Long battery life, approx. 1 year. (batteries included)
High accurate digital readings.
Clean and Safety
Here are our top four tips.
1. Always clean you stainless steel probe after use.
2. Pay close attention to the direction of the probe's sharp tip.
3. If the LCD begins to fade, change your batteries.
4. To avoid electrical shock avoid contact with surfaces of 24 VAC or 60 VDC.
Thank you for considering Milwaukee to help you take your results to the next level.
The Milwaukee EC60 PRO Conductivity Tester is designed for hydroponic and other growers to help you make sure that your plants have the ideal amount of nutrient avaiable. Keep EC in your target range to help your achieve better results.
DESIGN FEATURES
Measures conductivity and TDS with automatic temperature compensation
Ideal range for hydroponic and other growers (0.00 to 20.00 mS/cm)
Units in mS/cm or ppt easily convertible to ppm
Factory calibrated with the ability to recalibrate if needed
Replaceable electrode
Fully waterproof to IP65
Approximately 100 hours of use (4 x 1.5V batteries included)
CARE AND USE
MAINTENANCE
EC electrodes can develop nutrient build up over time. To miminise build up, always rinse the probe in fresh tap water after every use.
CONVERTING EC TO TDS
The Milwaukee EC60 PRO Conductivity Tester, like all conductivity meters, provides a measure of electrically charged ions in a solution and is an absolute measure of conductivity.
In Hydroponics, EC is often converted to TDS in parts per million (ppm). Different scales include the 500 scale, 650 scale and the 700 scale. However, true PPM can only be determined through chemical analysis.
Your mS/cm reading can be approximately converted to TDS (ppm) as shown in the examples below.
2.00 mS/cm = 2000 uS/cm = 1000 ppm on .50 factor scale
2.00 mS/cm = 2000 uS/cm = 1400 ppm on the 442 scale or .70 factor scale
MW401 is a Portable Low Range Total Dissolved Solids (TDS) Meter with Automatic Temperature Compensation. This instrument has been designed for aquariums, aquaculture, labs, and water conditioning applications to meet the needs for equipment suited from hobbist to professional. It is also a great meter for food labs, and water treatment applications.
TDS testing provides a method to optimize chemical applications and minimize operational cost. In aquarium and aquaculture applications, high concentrations of solids (TDS) can reduce clarity in water can decrease photosynthesis in aquatic plants. In water conditioning, a high (TDS) level can affect the clarity and taste of potable drinking water.
The MW401 has a range of 0 to 1990 mg/L (ppm) with a 10 mg/L (ppm) resolution. This (TDS) meter is supplied complete with conductivity probe with 1 m (3.3') cable and calibration solution.
DESIGN FEATURES
0 to 1999 mg/l (ppm) range.
Fast, easy-to-read results with large digital LCD readout.
Supplied with conductivity probe attached to a 3 foot cable.
Accuracy to ±2% FS @ 25°C.
Lightweight and portable.
300 hours of battery life with continuous use (battery included).
SE510 Conductivity probe included.
Starter Calibration Solution MI0032B, 1382 ppm (included).