Probe calibration is a simple procedure for optimal performance and should be done any time your readings become suspect. Calibration should be performed at least once a month.
M10007B is a lab grade pH 7.01 calibration solution certified to meet the standard with an accuracy of ±0.01 pH removing the inaccuracies involved with mixing solutions from powder.
Sachet packaging means that you get fresh solution every time. Ideal for infrequent or field use. No risk of using an expired calibration solution.
Milwaukee solutions are designed to help you achieve reliable and repeatable pH measurements while extending the life of your electrode.
DESIGN FEATURES
pH 7.01 Calibration Buffer Solution - 20 mL
Fundamental for the correct use of electrodes and for obtaining the most accurate and reproducible readings
Sealed against light and air
Ideal for on-the-spot calibration
Simply open, insert the tester or electrode into the sachet and calibrate
Formulated with a 5 year expiry
Colour coded for easy identification
Convenient pH Calibration Solution
The Milwaukee M10004B pH 4.01 Calibration Solution Sachet is the perfect tool for calibrating your pH meters and testers. Each sachet contains a pre-measured amount of pH solution, making calibration quick and easy. Simply open the sachet, pour the solution into your device, and you're ready to go. No more measuring and mixing solutions – just fast, accurate calibration every time.
Precise pH Measurement
This calibration solution is formulated to give you precise pH readings, ensuring the accuracy of your pH meters and testers. With a pH value of 4.01, it provides a reliable reference point for calibration. Whether you're testing water quality, soil acidity, or any other pH-dependent process, this solution will help you get the most accurate results possible.
Single-Use Sachets
Each Milwaukee M10004B pH 4.01 Calibration Solution Sachet is designed for single use, eliminating the need for storage and potential contamination. This ensures that every calibration is fresh and accurate, giving you confidence in your results. With these convenient sachets, calibration has never been easier or more reliable.
MA9015 is a lab grade electrode storage solution prepared with premium chemicals to improve the performance and extend the life of your pH and ORP electrodes, testers and pens.
To ensure a quick response and free-flowing liquid junction, the sensing element and reference junction must not be allowed to dry out. Properly storing your pH electrode in a solution keeps the glass membrane well hydrated which maintains proper function and provides accurate readings.
MA9015 also helps keep the junction in your pH and ORP electrode flowing which is critical for fast results.
DESIGN FEATURES
Fundamental for the correct use of electrodes and for obtaining the most accurate and reproducible readings.
Formulated to minimize organic growth on your electrode.
Sealed against light with air tight, tamper proof cap.
Factory blended to precise standards in a dedicated, temperature controlled environment.
Simply open and add to the cap of your electrode or tester.
Each bottle marked with lot number and expiration date.
Probe calibration is a simple procedure for optimal performance and should be done any time your readings become suspect. Calibration should be performed at least once a month.
M10010B is a lab grade pH 10.01 calibration solution certified to meet the standard to an accuracy of ±0.01 pH removing the inaccuracies involved with mixing from powder.
Sachet packaging means that you get fresh solution every time. Ideal for infrequent or field use. No risk of using an expired or contaminated solution.
Milwaukee solutions are designed to help you achieve reliable and repeatable pH measurements while extending the life of your electrode.
DESIGN FEATURES
pH 10.01 Calibration Buffer Solution - 20 mL
Fundamental for the correct use of electrodes and for obtaining the most accurate and reproducible readings
Sealed against light and air
Ideal for on-the-spot calibration
Simply open, insert the tester or electrode into the sachet and calibrate
Formulated with a 5 year expiry
Colour coded for easy identification
The MA9071 electrolyte fill solution is designed for Milwaukee's polarographic dissolved oxygen probe. A high quality electrolyte solution is crucial to the performance of your dissolved oxygen probe.
DESIGN FEATURES
PRECISE FORMULATION
Factory mixed using reagent grade chemicals in a dedicated, temperature controlled environment.
TRACEABLE
Product labeled with product code, lot number and expiration date.
SECURE
Air tight bottle with tamper-proof seal.
USE AND CARE
“OPEN AIR” CALIBRATION PROCEDURE FOR THE MW600 DISSOLVED OXYGEN METER
1. Remove the membrane
Take the membrane off the end of the probe and dry the diode off.
2. Zero out the display
Connect the probe to the base unit and turn the unit on. Your display should read 0.0. If it does not, go to the position “0” screw on the front of the unit with the screw driver provided and through the access hole make the unit display read 0.0.
3. Fill the membrane
Go to the membrane and put the “O” ring inside the membrane on the shoulder at the base of the threads. Fill the membrane to just short of the “O” ring with MA9071 electrolyte solution. Be sure that there are no bubbles inside the membrane. (Air bubbles are the main cause of calibration failure)
4. Attach the membrane
Screw the membrane on to the probe.
5. Let stabilize
Turn the meter on and hang the probe off the end of a table pointing down and let the unit display stabilize (this may take 5 to 15 minutes)
6. Adjust
Push down and hold the “Cal” button on the front face of the meter and with the screwdriver go to the front Cal position “100%” and make the display read 100.
You are now calibrated.
EXTRA TIPS
Watch for the membrane having wrinkles or stretch marks. If you see wrinkles, replace with a new membrane.
Always use fresh electrolyte solution (MA9071).
MA9016 is a lab grade electrode cleaning solution prepared with premium chemicals to improve the performance and extend the life of your pH and ORP electrodes, testers and pens.
Your accuracy and speed of your results are dependent on your pH sensing bulb and ORP platinum tip being clean. pH and ORP electrodes also need a free flowing junction to function.
Milwaukee's cleaning solution helps both keep sensing parts clean and the junction open. Simply open the bottle, fill a beaker or container so that the level covers the sensor and junction, and soak for 15 to 20 minutes followed by a soaking in MA9015 storage solution for at least 2 hours.
DESIGN FEATURES
Fundamental for the correct use of electrodes and for obtaining the most accurate and reproducible readings.
Specially formulated for cleaning electrodes
Factory blended to precise standards in a dedicated, temperature controlled environment.
Sealed against light with air tight, tamper proof cap.
Each bottle marked with lot number and expiration date.
High Quality Solution
Milwaukee MA9070 Zero Oxygen Calibration Solution Kit offers high-quality solution for calibrating oxygen levels in your equipment. The kit contains all the necessary components to ensure accurate and reliable calibration results each time. With this kit, you can rest assured that your devices are properly calibrated for precise readings.
Easy to Use
This calibration solution kit is designed for easy and convenient use. Simply follow the instructions provided in the kit to calibrate your equipment with ease. The user-friendly design makes it suitable for both professionals and beginners. You can trust Milwaukee MA9070 to deliver consistent and accurate results without any hassle.
Reliable Performance
Milwaukee MA9070 Zero Oxygen Calibration Solution Kit is known for its reliable performance and durability. It is built to last and withstand frequent use in various settings. Whether you are working in a laboratory, industrial facility, or research environment, this kit is designed to meet your calibration needs. Invest in Milwaukee MA9070 for dependable performance every time.
The performance of conductivity probes are affected by use due to residue build up and aging.
M10032B is a lab grade 1382 ppm TDS solution standard prepared against a NIST traceable potassium chloride solution that allows you to recalibrate your conductivity meter or tester. Check your meter or tester's manual to find the correct calibration standard for your meter.
TDS readings are effected by temperature. To help with this, a chart of the actual ppm value at various temperatures is printed on each sachet.
Milwaukee TDS solutions are labelled with the lot number and expiration date and packaged in an air tight, tamper-proof sachet.
DESIGN FEATURES
Fundamental for accurate TDS measurement.
Factory calibrated with potassium chloride NIST 2202 SRM (Standard Reference Material) in deionized water for analytical use in accordance with ISO 3696/BS3978.
Sealed against light and air.
Ideal for on-the-spot calibration
Simply open, insert the tester or electrode into the sachet and calibrate
Each 20 mL sachet is marked with lot number and expiration date.
A temperature chart of the actual ppm value at various temperatures is printed on each sachet.
5 year expiry date.
Electrode cleaning solution is ideal for cleaning all pH, ORP and TDS meter's probes. To help maintain high performance and accuracy for any electrode, regular cleaning is required to remove the build up of dirt and sediment on the glass or carbon surfaces of a sensing probe. Use M10016B to help extend the life of the meter's electrode.
Electrode cleaning solution should not be a substitute for rinse and or storage solutions.
Sachet packaging means that you get fresh solution every time. Ideal for infrequent or field use. No risk of using an expired calibration solution.
Milwaukee cleaning solutions are designed to help you achieve reliable and repeatable measurements while extending the life of your electrode.
DESIGN FEATURES
Electrode Cleaning Solution - 20 mL (box of 25).
Fundamental for gently cleaning the electrode between uses and before storage.
Sealed against light and air.
Ideal for on-the-spot cleaning too.
Simply open, insert the tester or electrode into the sachet and gently stir let soak for 15 minutes.
Formulated with a 5 year expiry
The performance of conductivity probes are affected by use due to residue build up and aging. M10031B is a lab grade 1413 µS/cm conductivity solution standard prepared against a NIST traceable potassium chloride solution that allows you to recalibrate your conductivity meter or tester. Check your meter or tester's manual to find the correct calibration standard for your meter. Conductivity readings are effected by temperature. To help with this, a chart of the actual µS/cm value at various temperatures is printed on each sachet. Milwaukee conductivity solutions are labeled with the lot number and expiration date and packaged in an air tight, tamper-proof sachet. Design Features Fundamental for accurate conductivity measurement. Factory calibrated with potassium chloride NIST 2202 SRM (Standard Reference Material) in deionized water for analytical use in accordance with ISO 3696/BS3978. Sealed against light and air. Ideal for on-the-spot calibration Simply open, insert the tester or electrode into the sachet and calibrate Each 20 mL sachet is marked with lot number and expiration date. A temperature chart of the actual µS/cm value at various temperatures is printed on each sachet. 5 year expiry date.
Probe calibration is a simple procedure for optimal performance and should be done any time your readings become suspect. Calibration should be performed at least once a month.
M10007B is a lab grade pH 7.01 calibration solution certified to meet the standard with an accuracy of ±0.01 pH removing the inaccuracies involved with mixing solutions from powder.
Sachet packaging means that you get fresh solution every time. Ideal for infrequent or field use. No risk of using an expired calibration solution.
Milwaukee solutions are designed to help you achieve reliable and repeatable pH measurements while extending the life of your electrode.
DESIGN FEATURES
pH 7.01 Calibration Buffer Solution - 20 mL
Fundamental for the correct use of electrodes and for obtaining the most accurate and reproducible readings
Sealed against light and air
Ideal for on-the-spot calibration
Simply open, insert the tester or electrode into the sachet and calibrate
Formulated with a 5 year expiry
Colour coded for easy identification
The performance of conductivity probes are affected by use due to residue build up and aging.
M10038B is a lab grade 6.44 ppt TDS solution standard prepared against a NIST traceable potassium chloride solution that allows you to recalibrate your conductivity meter or tester. Check your meter or tester's manual to find the correct calibration standard for your meter.
TDS readings are effected by temperature. To help with this, a chart of the actual ppm value at various temperatures is printed on each sachet.
Milwaukee TDS solutions are labelled with the lot number and expiration date and packaged in an air tight, tamper-proof sachet.
DESIGN FEATURES
Fundamental for accurate TDS measurement.
Factory calibrated with potassium chloride NIST 2202 SRM (Standard Reference Material) in deionized water for analytical use in accordance with ISO 3696/BS3978.
Sealed against light and air.
Ideal for on-the-spot calibration
Simply open, insert the tester or electrode into the sachet and calibrate
Each 20 mL sachet is marked with lot number and expiration date.
A temperature chart of the actual ppm value at various temperatures is printed on each sachet.
5 year expiry date.
accurate pH calibration
Ensure precise calibrations with the Milwaukee M10004B pH 4.01 Calibration Solution Sachet. This pack contains 25 individual sachets of pH 4.01 solution, providing a reliable option for calibrating pH meters and electrodes. Each sachet is conveniently pre-measured for easy use and eliminates the need for measuring out liquid solutions.
high-quality formulation
The Milwaukee M10004B pH 4.01 Calibration Solution Sachet is made with high-quality ingredients to ensure accuracy and consistency in pH readings. The solution is specially formulated to maintain a pH level of 4.01, making it ideal for calibrating a wide range of pH meters used in various applications. Trust this reliable solution for your calibration needs.
convenient packaging
Each sachet in the Milwaukee M10004B pH 4.01 Calibration Solution pack is individually sealed to prevent contamination and maintain freshness. The compact size of the sachets makes them easy to store and transport, providing convenience for both laboratory and field use. Stay prepared with this convenient pack of calibration solutions for your pH testing equipment.
Probe calibration is a simple procedure for optimal performance and should be done any time your readings become suspect. Calibration should be performed at least once a month.
M10010B is a lab grade pH 10.01 calibration solution certified to meet the standard to an accuracy of ±0.01 pH removing the inaccuracies involved with mixing from powder.
Sachet packaging means that you get fresh solution every time. Ideal for infrequent or field use. No risk of using an expired or contaminated solution.
Milwaukee solutions are designed to help you achieve reliable and repeatable pH measurements while extending the life of your electrode.
DESIGN FEATURES
pH 10.01 Calibration Buffer Solution - 20 mL
Fundamental for the correct use of electrodes and for obtaining the most accurate and reproducible readings
Sealed against light and air
Ideal for on-the-spot calibration
Simply open, insert the tester or electrode into the sachet and calibrate
Formulated with a 5 year expiry
Colour coded for easy identification
Optimal Calibration Solution
Ensure accurate conductivity measurements with the Milwaukee M10030B 12880 µS/cm Conductivity Calibration Solution Sachet. This high-quality solution is specially designed for calibrating conductivity meters, ensuring precise and reliable readings every time. Each sachet comes pre-measured for convenience, making calibration a quick and hassle-free process.
Quality Control Standards
Formulated to meet strict quality control standards, this calibration solution provides consistent results for your conductivity measurements. The 12880 µS/cm value is ideal for a wide range of applications, from testing water quality to monitoring industrial processes. Trust Milwaukee's expertise in producing reliable calibration solutions for all your conductivity needs.
High-quality pH7 calibration solution
Oxyguard pH7 Buffer is the ideal choice for calibrating and testing pH meters and probes. This premium calibration solution ensures accurate results every time, giving you peace of mind during your experiments or testing procedures. With a pH level of 7.00, this buffer solution is formulated to bring your pH meter back to its original factory settings, ensuring precise and reliable measurements.
Easy-to-use formula for hassle-free calibration
With Oxyguard pH7 Buffer, calibrating your pH meter is quick and effortless. Simply immerse your probe into the solution and adjust the readings accordingly to achieve accurate results. This buffer solution is easy to use, making it perfect for both beginners and experienced professionals in the field. Say goodbye to complicated calibration procedures with our convenient pH7 buffer solution!
Reliable and consistent results guaranteed
When it comes to pH calibration and testing, trust Oxyguard pH7 Buffer to deliver reliable and consistent results. Our high-quality formula ensures that your pH meter remains accurate and precise, providing you with the confidence you need in your lab or testing environment. Whether you are conducting research or performing routine measurements, Oxyguard pH7 Buffer is the perfect solution for all your calibration and testing needs.
MA9020 is a lab grade ORP 200-275 mV solution certified to meet the range. MA9020 is used to check the health and accuracy of an ORP electrode.
Milwaukee solutions are designed to help you achieve reliable and repeatable ORP measurements.
DESIGN FEATURES
OPR 200-275 mV solution value (230 mL).
Fundamental for the correct use of ORP electrodes and for obtaining the most accurate and reproducible readings.
Sealed against light with air tight, tamper proof cap.
Ideal for fast accuracy check.
Simply open, pour into a beaker or container and insert the tester or electrode to start the ORP mV check process.