MA9016 is a lab grade electrode cleaning solution prepared with premium chemicals to improve the performance and extend the life of your pH and ORP electrodes, testers and pens.
Your accuracy and speed of your results are dependent on your pH sensing bulb and ORP platinum tip being clean. pH and ORP electrodes also need a free flowing junction to function.
Milwaukee's cleaning solution helps both keep sensing parts clean and the junction open. Simply open the bottle, fill a beaker or container so that the level covers the sensor and junction, and soak for 15 to 20 minutes followed by a soaking in MA9015 storage solution for at least 2 hours.
DESIGN FEATURES
Fundamental for the correct use of electrodes and for obtaining the most accurate and reproducible readings.
Specially formulated for cleaning electrodes
Factory blended to precise standards in a dedicated, temperature controlled environment.
Sealed against light with air tight, tamper proof cap.
Each bottle marked with lot number and expiration date.
The Milwaukee Waterproof pH51 Tester is one of our most accurate low cost, rugged and reliable pH testers in the market featuring the ability to easily replace the probe providing for years of carefree use. It's simple 2 point manual calibration is simple-to-use. Ideal for use in aquariums, hydroponics, horticulture, pools and many other applications.
The Milwaukee pH51 pH tester offers:
ACCURACY
The Waterproof pH51 tester is accurate to ±0.1 pH and is easy to read.
With easy 2 point manual calibration, this pH tester is quickly calibrated to an accuracy of much more expensive meters. Simple design and rugged, it brings great value for any application. Why guess at your readings using litmus paper when you can have guaranteed accurate, digital LCD results.
LONG LIFE
The tester comes with a replaceable pH probe with a double junction probe designed for longer life.
FAST RESPONSE
The probe is double junction allowing quick, accurate pH readings and respose times.
WATERPROOF CONSTRUCTION
No more worries about dropping your tester while measuring. The pH51 is waterproof to IP65.
LIGHT WEIGHT
At just 3.5 ounces, the pH51 is easy to handle at up to half the weight of other testers.
EASE-OF-USE
A large LCD screen makes reading results easy while calibrating or reading your measurement. This takes the takes the guess work out of litmus paper.
DESIGN FEATURES
Fast easy to read results with large digital LCD readout.
Extreme pH accuracy to ±0.1 pH with a pH range (0.0 pH to 14.0 pH).
Lightweight and portable.
Easy measurement: just place the probe in the sample, gently stir, wait for the stability indication to show a stable reading and then freeze the reading.
Simple manual one or two-point calibration.
Gel-filled, double junction pH electrode for low maintenance and high performance.
Fully waterproof to IP65.
Over 1500 hours of continuous battery life (batteries included).
Replaceable pH electrode.
CARE AND USE
All pH sensors have a limited life and response time gets longer with age. Properly maintaining your pH pen tester will give you fast, accurate results for longer. So, be sure to order the Milwaukee pH Maitenance Kit code PH-Main at checkout time! This will be needed to help clean and condition the pH electrode before use!
Here are our top four tips.
1. Always store with the cap full of buffer or storage solution MA9015 not water.
2. Clean your Tester regularly by soaking in cleaning solution MA9016.
3. Calibrate after cleaning and/or storage before testing to adjust for changes in the pH sensor.
4. Gently stir the Tester in the sample for a faster result.
Thank you for considering Milwaukee to help you take your results to the next level.
Electrode cleaning solution is ideal for cleaning all pH, ORP and TDS meter's probes. To help maintain high performance and accuracy for any electrode, regular cleaning is required to remove the build up of dirt and sediment on the glass or carbon surfaces of a sensing probe. Use M10016B to help extend the life of the meter's electrode.
Electrode cleaning solution should not be a substitute for rinse and or storage solutions.
Sachet packaging means that you get fresh solution every time. Ideal for infrequent or field use. No risk of using an expired calibration solution.
Milwaukee cleaning solutions are designed to help you achieve reliable and repeatable measurements while extending the life of your electrode.
DESIGN FEATURES
Electrode Cleaning Solution - 20 mL (box of 25).
Fundamental for gently cleaning the electrode between uses and before storage.
Sealed against light and air.
Ideal for on-the-spot cleaning too.
Simply open, insert the tester or electrode into the sachet and gently stir let soak for 15 minutes.
Formulated with a 5 year expiry
The performance of conductivity probes are affected by use due to residue build up and aging.
M10032B is a lab grade 1382 ppm TDS solution standard prepared against a NIST traceable potassium chloride solution that allows you to recalibrate your conductivity meter or tester. Check your meter or tester's manual to find the correct calibration standard for your meter.
TDS readings are effected by temperature. To help with this, a chart of the actual ppm value at various temperatures is printed on each sachet.
Milwaukee TDS solutions are labelled with the lot number and expiration date and packaged in an air tight, tamper-proof sachet.
DESIGN FEATURES
Fundamental for accurate TDS measurement.
Factory calibrated with potassium chloride NIST 2202 SRM (Standard Reference Material) in deionized water for analytical use in accordance with ISO 3696/BS3978.
Sealed against light and air.
Ideal for on-the-spot calibration
Simply open, insert the tester or electrode into the sachet and calibrate
Each 20 mL sachet is marked with lot number and expiration date.
A temperature chart of the actual ppm value at various temperatures is printed on each sachet.
5 year expiry date.
The Milwaukee EC59 PRO Conductivity (EC) & Total Dissolved Solids (TDS) Tester is designed for aquaculture, food, wine, laboratory, water treament and many other applications. It is the ideal meter to help make sure that your EC/TDS/Temp. needs are being met and are reliable results for your analysis. Keep EC/TDS/TEMP. in your target range to help your achieve best results.
DESIGN FEATURES
Measures EC/TDS/Temp. with automatic temperature compensation (ATC).
Ideal range for all different applications (0 to 3999 uS/cm) | 0 to 2000 ppm | 0.0 to 60°C (32.0 to 140.0°F).
Units in uS/cm or ppm easily convertable to other ranges.
Factory calibrated with the ability to recalibrate if needed.
Replaceable electrode Mi59P.
Fully waterproof to IP65.
Approximately 100 hours of use (4 x 1.5V batteries included).
CARE AND USE
MAINTENANCE
EC electrodes can develop nutrient build up over time. To miminize build up, always rinse the probe in fresh tap water after every use.
CONVERTING EC TO TDS
The Milwaukee PRO Conductivity Tester, like all conductivity meters, provides a measure of electrically charged ions in a solution and is an absolute measure of conductivity.
EC/TDS can converted. Different scales include the 500 scale, 650 scale and the 700 scale.
Your uS/cm reading can be approximately converted to other scales as shown in the examples below.
2.00 mS/cm = 2000 uS/cm = 1000 ppm on .50 factor scale
2.00 mS/cm = 2000 uS/cm = 1400 ppm on the 442 scale or .70 factor scale
Over 200,000 people have relied on the Milwaukee pH600AQ compact pH pen tester to move from difficult to use and interpret pH strips to digital testing.
SUMMARY
The Milwaukee pH600AQ compact pen tester is specifically designed to help maintain aquariums and aquaculture. Keeping the proper pH improves results for aquarium fish and quality in a range of fish raised in aqulculture.
Use digital accuracy to keep pH in your target range for better results.
WHAT PEOPLE ARE SAYING
"Accurate results and calibrated right out of the box."
"Must have for any aquarium owner."
"Good value. Easy to use. Consistent."
DESIGN FEATURES
Fast, accurate results with digital LCD readout
Easy measurement: just place the probe in the sample, gently stir and wait for the reading to stabilize
Simple one-point calibration with an easy-to-use trimmer located on the back of the pH tester to protect from accidental splashes
Cap to protect the pH sensor and keep it wet when stored upright
Low power demand for extended battery life (batteries included)
USE AND CARE
All pH sensors have a limited life and response time gets longer with age. Properly maintaining your pH pen tester will give you fast, accurate results for longer. So, be sure to order the Milwaukee pH Maintenance Kit code PH-Main at checkout time! This will be needed to help clean and condition the pH electrode before use!
Here are our top four tips.
1. Always store upright with the cap full of buffer or storage solution MA9015 not water.
2. Clean your pH Pen Tester regularly by soaking in cleaning solution MA9016.
3. Calibrate after cleaning and/or storage before testing to adjust for changes in the pH sensor.
4. Gently stir the Pen in the sample for a faster result.
Thank you for considering Milwaukee to help you take your results to the next level.
The MA9070 Zero Oxygen Calibration Solution Kit is made up of two components for use in calibrating the Milwaukee MW600 DO Meter.
Design Features
Easy to use
Simple mix the two components and place in solution to quickly calibrate to 0% oxygen concentration
Traceable
Product labeled with product code, lot number and expiration date
Secure
Air tight bottle with tamper-proof seal
The Milwaukee T75 Waterproof Total Dissolved Solids (TDS) Pen is designed for, aquariums, aquaculture, education, water conditioning and many other applications. The T75 helps you make sure that your fish have the right TDS balance to help them stay healthy. TDS also help keep filters up-to-date and clean for water filtration. Keep TDS in your target range to help your achieve better results.
DESIGN FEATURES
Measures Total Dissolved (TDS) direct and with automatic temperature compensation.
Easy-to-read LCD.
Ideal range for aquariums (0 to 1999 ppm).
Units in ppm easily convertible to uS/cm.
Factory calibrated with the ability to recalibrate if needed.
250 hours continuous use (3 x 1.5V batteries included).
Simple one point calibration.
Fully waterproof to IP65
Replaceable TDS electrode MA73075.
CARE AND USE
MAINTENANCE
TDS/PPM electrodes can develop nutrient build up over time. To miminice build up, always rinse the probe in fresh tap or DI water after every use.
CONVERTING TDS TO EC
The Milwaukee TDS Pen, like all TDS meters, provides a measure of Total Dissolved Solids (ppm) reading, of contaminates per unit of volume in a solution.
TDS/PPM is often converted to uS/cm. Different scales include the 500 scale, 650 scale and the 700 scale.
Your TDS/PPM readings can be approximately converted to uS/cm as shown in the examples below.
1 ppm = 2 uS/cm on the 0.5 factor scale
1 ppm = 1.43 µS/cm on the 442 scale or .70 factor scale
Thank you for considering Milwaukee to help you take your results to the next level.
The Milwaukee CD600 Total Dissolved Solids (TDS) Pen is designed for hydroponics, aquariums, horticulture, water conditioning and many other applications. The CD600 helps you make sure that your plants are receiving the right amount of nutrient or helps you keep your filters up-to-date and clean for water filtration. Keep TDS in your target range to help your achieve better results.
DESIGN FEATURES
Measures Total Disolved (TDS) direct and with automatic temperature compensation.
Ideal range for hydroponics (0 to 1990 ppm).
Units in ppm easily convertable to uS/cm.
Factory calibrated with the ability to recalibrate if needed.
Automatic Temperature Compensation (ATC).
350 hours continuous use (4 x 1.5V batteries included).
Simple one point calibration.
CARE AND USE
MAINTENANCE
TDS/PPM electrodes can develop nutrient build up over time. To miminize build up, always rinse the probe in fresh tap or DI water after every use.
CONVERTING TDS TO EC
The Milwaukee TDS Pen, like all TDS meters, provides a measure of Total Dissolved Solids (ppm) reading, of contaminates per unit of volume in a solution.
TDS/PPM is often converted to uS/cm. Different scales include the 500 scale, 650 scale and the 700 scale.
Your TDS/PPM readings can be approximately converted to uS/cm as shown in the examples below.
1 ppm = 2 uS/cm on the 0.5 factor scale
1 ppm = 1.43 µS/cm on the 442 scale or .70 factor scale
Thank you for considering Milwaukee to help you take your results to the next level.
The performance of conductivity probes are affected by use due to residue build up and aging. M10031B is a lab grade 1413 µS/cm conductivity solution standard prepared against a NIST traceable potassium chloride solution that allows you to recalibrate your conductivity meter or tester. Check your meter or tester's manual to find the correct calibration standard for your meter. Conductivity readings are effected by temperature. To help with this, a chart of the actual µS/cm value at various temperatures is printed on each sachet. Milwaukee conductivity solutions are labeled with the lot number and expiration date and packaged in an air tight, tamper-proof sachet. Design Features Fundamental for accurate conductivity measurement. Factory calibrated with potassium chloride NIST 2202 SRM (Standard Reference Material) in deionized water for analytical use in accordance with ISO 3696/BS3978. Sealed against light and air. Ideal for on-the-spot calibration Simply open, insert the tester or electrode into the sachet and calibrate Each 20 mL sachet is marked with lot number and expiration date. A temperature chart of the actual µS/cm value at various temperatures is printed on each sachet. 5 year expiry date.
The Milwaukee EC59 PRO Conductivity (EC) & Total Dissolved Solids (TDS) Tester is designed for aquaculture, food, wine, laboratory, water treament and many other applications. It is the ideal meter to help make sure that your EC/TDS/Temp. needs are being met and are reliable results for your analysis. Keep EC/TDS/TEMP. in your target range to help your achieve best results.
DESIGN FEATURES
Measures EC/TDS/Temp. with automatic temperature compensation (ATC).
Ideal range for all different applications (0 to 3999 uS/cm) | 0 to 2000 ppm | 0.0 to 60°C (32.0 to 140.0°F).
Units in uS/cm or ppm easily convertable to other ranges.
Factory calibrated with the ability to recalibrate if needed.
Replaceable electrode Mi59P.
Fully waterproof to IP65.
Approximately 100 hours of use (4 x 1.5V batteries included).
CARE AND USE
MAINTENANCE
EC electrodes can develop nutrient build up over time. To miminize build up, always rinse the probe in fresh tap water after every use.
CONVERTING EC TO TDS
The Milwaukee PRO Conductivity Tester, like all conductivity meters, provides a measure of electrically charged ions in a solution and is an absolute measure of conductivity.
EC/TDS can converted. Different scales include the 500 scale, 650 scale and the 700 scale.
Your uS/cm reading can be approximately converted to other scales as shown in the examples below.
2.00 mS/cm = 2000 uS/cm = 1000 ppm on .50 factor scale
2.00 mS/cm = 2000 uS/cm = 1400 ppm on the 442 scale or .70 factor scale
Probe calibration is a simple procedure for optimal performance and should be done any time your readings become suspect. Calibration should be performed at least once a month.
M10007B is a lab grade pH 7.01 calibration solution certified to meet the standard with an accuracy of ±0.01 pH removing the inaccuracies involved with mixing solutions from powder.
Sachet packaging means that you get fresh solution every time. Ideal for infrequent or field use. No risk of using an expired calibration solution.
Milwaukee solutions are designed to help you achieve reliable and repeatable pH measurements while extending the life of your electrode.
DESIGN FEATURES
pH 7.01 Calibration Buffer Solution - 20 mL
Fundamental for the correct use of electrodes and for obtaining the most accurate and reproducible readings
Sealed against light and air
Ideal for on-the-spot calibration
Simply open, insert the tester or electrode into the sachet and calibrate
Formulated with a 5 year expiry
Colour coded for easy identification